Ventilation Air Outdoors - New Buck Corporation Buck Stove FP-327-ZC Instruction Manual

Buck stoves model fp-327-zc instruction manual
Table of Contents

Advertisement

THIS APPLIANCE MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT,
POOR FUEL COMBUSTION COULD RESULT.
INSTRUCTIONS TO ENSURE PROPER FRESH AIR FOR THIS AND OTHER FUEL-
BURNING APPLIANCES IN YOUR HOME.
VENTILATION AIR FROM OUTDOORS
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent
openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items
directly to the outdoors. These spaces include attics and crawl spaces. Follow the National
Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, "Air For Combustion and Ventilation"
for required size of ventilation grills or ducts.
IMPORTANT:
Do not provide openings for inlet air into attic if attic has a thermostat-
controlled power vent. Heated air entering the attic will activate the power unit.
OUTLET AIR
INLET AIR
WARNING
VENTILATED ATTIC
OUTLET AIR
INLET AIR
FIGURE 8
Page 17
READ THE FOLLOWING
TO ATTIC
TO
CRAWL
SPACE
VENTILATED
CRAWL SPACE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents