Out Side Air Installation - New Buck Corporation 74 User Manual

Non-catalytic unit fireplace insert & freestanding
Hide thumbs Also See for 74:
Table of Contents

Advertisement

This model is designed for connection to any 2100° UL 103 HT chimneys. Follow chimney manufacturer's
instructions carefully.
Drop cloth, 3/32" Metal drill bit, 5/16" magnetic socket chuck adapter, 5/16" wrench (box or socket) or adjustable
wrench, Jigsaw with masonry, metal and wood blades
WARNING: DO NOT INSTALL IN A SLEEPING ROOM.
PREPARING STOVE FOR INSTALLATION
1. Remove protective plastic wrapping from unit, inspect unit for any obvious physical damage.
2. Plug power cord into a 115V AC outlet to test motor and fan when optional motor is being used. "Do not run
power cord under unit or in high traffic areas".
3. Check primary air draft control to ensure that it slides freely.(See Figure 12).
4. Remove any items from within firebox. Spread a dropcloth on floor behind heater. Next, tilt heater so that back
is on drop cloth.
. (Leg Kit): If legs are to be used, obtain four legs, attach legs to holes in bottom of unit with bolts and washers
5
supplied with leg kit. (See Figure 12).
6. (Pedestal Kit): If pedestal kit is being used (and out side air is required see below, Out Side Air Installation).
Open freestanding kit and obtain stand. Place stand against bottom of heater (angle side to heater).
Center stand front to rear and also center stand left and right. Mark screw locations on bottom of stove through
outer holes of stand mounting angles. Set stand aside and drill four 7/32" holes in heater bottom. Before attaching
heater to the stand, take a large flat screwdriver or pliers and remove 2" x 2" knockout on bottom of unit.
(See Figure 12A). Then mount stand to bottom of heater with screws provided. (See Figure 12A).
7. Obtain four (4) 3/16" self-tapping screws and secure stand to heater.
8. Reposition heater to upright position.
PRIMARY AIR
DRAFT CONTROL
THE STRUCTURAL INTEGRITY OF MOBILE HOME FLOOR MUST BE MAINTAINED. (MOVE OPENING
TOOLS FOR INSTALLATION
Figure 12

Out Side Air Installation

AND/OR REPOSITION HEATER LOCATION IFNECESSARY).
HOLES FOR MOUNTING PEDESTAL
Figure 12A
CAUTION
Page 25
2" x 2"
KNOCKOUT

Hide quick links: