New Buck Corporation Buck Stove FP-327-ZC Instruction Manual page 25

Buck stoves model fp-327-zc instruction manual
Table of Contents

Advertisement

• If the pilot will not stay lit after several tries, turn the gas control knob to "OFF"
and call your service technician or gas supplier.
THERMO-PILE
THERMO-COUPLE
12.
Turn control knob counterclockwise
toggle switch to the "ON" position. The main burner should light.
13.
Close access panel door.
14.
Turn on all electrical power to the appliance.
15.
Set thermostat to desired setting.
NOTE: This unit may be used with an optional Wall Thermostat. If so, the Wall
Thermostat needs to be set at a higher temperature than the room temperature.
SHUTTING OFF UNIT
1.
Open access panel door located at bottom front of the appliance.
2. "If equip with thermostat set to lowest setting."
3. Turn control knob clockwise
4. Turn off all electric power to the appliance if service is to be performed.
5. Close access panel door.
SHUTTING OFF BURNER ONLY (Pilot stays lit.)
Turn control knob clockwise
DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL
SHUTOFF VALVE.
IGNITOR ELECTRODE
TO TURN OFF GAS TO
APPLIANCE
to the "OFF" position.
to the "PILOT" position.
CAUTION
Page 23
PILOT BURNER
to the "ON" position. Push the "ON/OFF"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents