Operating the Display Controller

The display controller allows you to easily adjust the input signal settings and image quality. In addition, you can assign
the frequently used functions to dedicated buttons.

Adjusting the Image Quality

1. Adjust the image quality by rotating each knob.
Use the slider that appears at the bottom of the screen as guide.
• SHARPNESS
Adjusts the sharpness of the image.
• CHROMA
Adjusts the color saturation of the image.
• BRIGHTNESS
Adjusts the black level of the image.
• CONTRAST
Adjusts the white level of the image.

Adjusting the Image Quality on CDL

1. Switch the CDL select switch to CDL.
2. Use the RGB select button to select the color to adjust.
3. Adjust the image quality by rotating each knob.
• POWER
Adjusts the gamma of the image.
• SATURATION
Adjusts the color saturation of the image.
RGB cannot be selected for SATURATION.
• OFFSET
Adjusts the black level of the image.
• SLOPE
Adjusts the white level of the image.
Note
• Press the RESET button above the relevant adjustment, to return to factory default. In "User 1-7" mode where you are
performing calibration, the setting returns to the value after calibration instead of the factory default.
• Warming-up is necessary to stabilize the brightness of the video display. Wait at least 10 minutes after turning on the power
before using.
• If no operation is performed for approximately 1 minute, OSD menu will disappear automatically. The slider will disappear
automatically if no operation is performed for approximately 10 seconds.
• The settings that cannot be set, are grayed out.
Setting options (underline indicates the
Item
POWER
0.50 to 4.00 (1.00) (Increments of 0.01)
0.000 to 2.000 (1.000) (Increments of 0.001)
SATURATION
OFFSET
-1.000 to 1.000 (0.000) (Increments of 0.001)
0.000 to 2.000 (1.000) (Increments of 0.001)