Manual Diagnostics (On/Off) "Daen - ALLIANCE BF3LLFSG401UN01 Programming Manual

Frontload washer
Table of Contents

Advertisement

Programming Control
33. Manual Diagnostics (On/Off)
"dAEn"
This option allows the owner to enable or disable the
manual diagnostics option. Refer to Testing Machine
and Electronic Control Functions section for more
information.
How to Program the Manual Diagnostics
(On/Off)
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad until "Prog" appears in the
display. Press the START (enter) keypad and
"AtS1" will appear in the display.
3. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the
programmable options until "dAEn" appears in
the display.
4. When "dAEn" appears in the display, press the
START (enter) keypad. The current Manual
Diagnostics status will appear in the display.
"on" = Option Enabled (factory default setting)
"oFF"= Option Disabled
5. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to change the current status.
6. Press the START (enter) keypad when the
desired status appears in the display. The next
option, "PtEn", will appear in the display.
NOTE: To program "PtEn" (Production Test Cycle
[On/Off]), refer to option 34. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the DELICATES 30 (<) keypad until the control
returns to Ready Mode.
82
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
34. Production Test Cycle (On/Off)
"PtEn"
This option allows the owner to enable or disable
access to the production test cycle. Refer to
Production Test Cycle section for more information.
How to Program the Production Test
Cycle (On/Off)
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad until "Prog" appears in the
display. Press the START (enter) keypad and
"AtS1" will appear in the display.
3. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the
programmable options until "PtEn" appears in
the display.
4. When "PtEn" appears in the display, press the
START (enter) keypad. The current Production
Test Cycle status will appear in the display.
"on" = Option Enabled (factory default setting)
"oFF"= Option Disabled
5. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to change the current status.
6. Press the START (enter) keypad when the
desired status appears in the display. The first
option, "AtS1", will appear in the display.
NOTE: To program "AtS1" (Vend Price #1), refer
to option 1. To program other options, refer to the
appropriate section.
How to Exit Programming Feature
Press the DELICATES 30 (<) keypad until the control
returns to Ready Mode.
802953