Assembly Notes
NOTE
Be sure to route the blower cables over the top of the lamp blower, not over the lamp housing.
♦
Adhere a heat shield to the portion of the fan housing that is inserted into the lamp housing.
♦
Adhere a PSA square to the label side of the blower.
♦
If necessary, replace the blower gasket on the lamp housing. The blower gasket must be in place
before you install the blower.
♦
Position the blower so that the pointed end is inserted into the lamp housing, and the holes on the
mounting tab fit over the registration pins on the lamp housing. Torque the M3x8 Plastite Torx screw
to 6 in/lbs (.68 Nm).
LP500 Series Service Manual
50