Changing The Status Polling Rate; Changing The Response Timeout - NEC Silentwriter 1765 Configuration Manual

Silentwriter 1700 series
Hide thumbs Also See for Silentwriter 1765:
Table of Contents

Advertisement

Changing the Status Polling Rate

The status polling rate determines how often the
NEC 1765 software requests updates from the LAN
card. The rate is defined in seconds with a default value
of 30 seconds and a range of 5 to 255 seconds.
1.
From the Printer Administration window select the
Time Definition option from the Option menu.
2.
The Time Definition dialog box displays the current
polling rate.
3.
Type the new polling rate in the Status Polling Rate
text box.
4.
Select the OK button to save the new information
and leave the Time Definition dialog box
Or
Select the Cancel button to keep the old information
and leave the Time Definition dialog box.
5–36
1765 Network Printer Configuration Guide

Changing the Response Timeout

The response timeout defines how long the NEC 1765
software waits for an update from the LAN card before
displaying an error message. The rate is defined in
seconds with a default value of 5 seconds and a range of
5 to 255 seconds.
1.
From the Printer Administration window select the
Time Definition option from the Option menu.
2.
The Time Definition dialog box displays the current
response timeout setting.
3.
Type the new response timeout setting in the
Response Timeout text box.
4.
Select the OK button to save the new information
and leave the Time Definition dialog box
Or
Select the Cancel button to keep the old information
and leave the Time Definition dialog box.