5. Sample Hold Phase Adjustment (PD-342 board)
Set the sampling hold timing of the LCD panel to optimum tim-
ing.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Perform "LCD Automatic Adjustment" and "V-COM
Adjustment" before this adjustment.
Note 2: Check that the data of page: 0, address: 10 is "00".
Switch setting
LCD BACKLIGHT .................................................................. ON
Adjusting method:
Order Page Address Data
1
0
01
2
3
71
3
3
0C
4
3
22
5
C
55
6
C
54
7
C
54
8
C
54
9
C
55
10
3
0C
11
3
22
12
3
70
13
3
70
14
0
01
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
VTR stop (PLAY/EDIT mode)
No signal
Check on LCD screen
C
54
The LCD screen is brightest
Procedure
01
01
Press PAUSE (Write) button.
20
Press PAUSE (Write) button.
0F
Press PAUSE (Write) button.
01
Press PAUSE (Write) button.
Set the following data, one
by one, and investigate which
data makes the LCD screen
the brightest.
1F, 3F, 5F, 7F, 9F, BF
Set the data which made the
LCD screen the brightest.
This data named Dadj.
D
Press PAUSE (Write) button.
adj
CC
Press PAUSE (Write) button.
00
Press PAUSE (Write) button.
00
Press PAUSE (Write) button.
10
Press PAUSE (Write) button.
Check the data changes to
"11".
00
6-66