28. White Defect Adjustment
Defect white defective pixels of CMOS image sensor.
Subject
Measurement Point
Measuring Instrument
Specified value
Note 1: Perform "HS White Defect Adjustment" before this ad-
justment.
Note 2: Perform adjustments successively, starting from the "HS
White Defect Adjustment".
Note 3: The lens thermistor data of the set must exceed 37 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 37 degrees.
Note 4: Check that the data of page: 0, address: 10 is "00".
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
1
0
01
2
6
02
3
6
E0
4
6
07
5
6
D0
6
6
01
7
8
6
02
9
6
D3
Note 5: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6: If the data is other than "25" to "50", perform the aging.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
0
01
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
RadarW
RadarW
RadarW
RadarW
RadarW
Not required
Adjusting remote commander
Data of page: 6 address: D3 is "00"
or "02" to "FF".
Procedure
01
Check the data is "00".
(Note 5)
Check the data is "25" to
"50". (Note 6)
Check the data is "04".
06
21
Press PAUSE (Write) button.
Wait for 10 seconds.
Check the data changes to
"01".
Check the data is "00" or
"02" to "FF".
Procedure
00
Press PAUSE (Write) button.
00
29. White Defect Adjustment (FD white point)
RadarW
RadarW
RadarW
Defect white defective pixels (FD white point) of CMOS image
sensor.
Subject
Note 1: Perform "White Defect Adjustment" before this adjust-
ment.
Note 2: Perform adjustments successively, starting from the "HS
White Defect Adjustment".
Note 3: The lens thermistor data of the set must exceed 37 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 37 degrees.
Note 4: Check that the data of page: 0, address: 10 is "00".
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
1
0
01
2
6
02
3
6
E0
4
6
07
5
6
D0
6
6
01
7
6
02
Note 5: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6: If the data is other than "25" to "50", perform the aging.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
0
01
6-59
Not required
Procedure
01
Check the data is "00".
(Note 5)
Check the data is "25" to
"50". (Note 6)
Check the data is "04".
0C
21
Press PAUSE (Write) button.
Check the data changes to
"01".
Procedure
00
Press PAUSE (Write) button.
00