Sony HVR-HD1000J Service Manual page 208

Digital hd video camera recorder
Table of Contents

Advertisement

Ver. 1.2 2008.04
30. White Defect Check
Subject
Measurement Point
Measuring Instrument
Specified value 1
Specified value 2
Note 1: Perform "White Defect Adjustment" before this adjust-
ment.
Note 2: Perform adjustments successively, starting from the "HS
White Defect Adjustment".
Note 3: The lens thermistor data of the set must exceed 37 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 37 degrees.
Note 4: Check that the data of page: 0, address: 10 is "00".
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
1
0
01
2
6
02
3
6
E0
4
6
07
5
6
D0
6
6
01
7
6
02
8
6
D1
6
D2
9
Note 5: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6: If the data is other than "25" to "50", perform the aging.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
0
01
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
RadarW
RadarW
RadarW
RadarW
RadarW
Not required
Adjusting remote commander
Data of page: 6 address: D1 is "00"
Data of page: 6, address: D2 is "00"
to "08"
Procedure
01
Check the data is "00".
(Note 5)
Check the data is "25" to
"50". (Note 6)
Check the data is "04".
04
21
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
Check the data is "00" to
"08".
Procedure
00
Press PAUSE (Write) button.
00
31. Black Defect Adjustment
Defect black defective pixels of CMOS image sensor.
Subject
Note 1: Perform "White Defect Adjustment" before this adjust-
ment.
Note 2: Perform adjustments successively, starting from the "HS
White Defect Adjustment".
Note 3: The lens thermistor data of the set must exceed 37 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 37 degrees.
Note 4: Shoot the clear chart with the zoom TELE end.
Note 5: Check that the data of page: 0, address: 10 is "00".
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
1
2
0
01
3
6
02
4
6
E0
5
6
07
6
6
2C
7
6
90
8
6
91
9
6
92
10
6
93
11
6
01
12
13
14
6
D0
15
6
01
6
02
16
Note 6: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 7: If the data is other than "25" to "50", perform the aging.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
90
3
6
91
4
6
92
5
6
93
6
6
01
7
8
6
01
9
6
2C
10
0
01
6-60
RadarW
RadarW
RadarW
Clear chart (All white) (Note 1)
Procedure
Turn off the power and turn
on again.
01
Check the data is "00".
(Note 6)
Check the data is "25" to
"50". (Note 7)
Check the data is "04"
01
00
04
00
10
79
Press PAUSE (Write) button.
Wait for 1.5 seconds.
Check that the entire screen
is white.
01
21
Press PAUSE (Write) button.
Check the data changes to
"01".
Procedure
00
Press PAUSE (Write) button.
00
00
00
00
79
Press PAUSE (Write) button.
Wait for 1.5 seconds.
00
Press PAUSE (Write) button.
00
00