Sony HVR-HD1000J Service Manual page 285

Digital hd video camera recorder
Table of Contents

Advertisement

4-4.
SERVICE MODE
Note: Before performing the adjustment, check the data of page:
0, address: 10 is "00". If not, select page: 0, address: 00,
and set data "00".
1. Setting the Test Mode
Page A
Data
00
Normal
01
Forced camera power ON (CAMERA-TAPE mode)
02
Forced VTR power ON (PLAY/EDIT mode)
03
Forced camera + VTR power ON
Forced memory power ON
05
(CAMERA-MEMORY mode)
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page A, the data set will be recorded in the non-volatile
memory by pressing the PAUSE (Write) button of the adjust-
ment remote commander. In this case, take note that the test
mode will not be exited even when the main power is turned off
(8.4 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE (Write) button of the
adjustment remote commander. And select page: 0, address: 01,
and set data: 00.
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
Address 10
Function
2. Emergence Memory Address
2-1. Emergence Memory Address (Mechanism
section)
Page C
Address
F4
EMG code when first error occurs
Upper: MSW code when shift starts when first error
F6
occurs
Lower: MSW code when first error occurs
Lower: MSW code to be moved when first error
F7
occurs
F8
EMG code when second error occurs
Upper: MSW code when shift starts when second
FA
error occurs
Lower: MSW code when second error occurs
Lower: MSW code to be moved when second error
FB
occurs
FC
EMG code when last error occurs
Upper: MSW code when shift starts when last error
FE
occurs
Lower: MSW code when last error occurs
Lower: MSW code to be moved when last error
FF
occurs
When no error occurs in this unit, data "00" is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (F4 to F7). In the same way, when the second error occurs,
the data corresponding to the error is written in the second emer-
gency address (F8 to FB).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (FC to FF).
Note: After completing adjustments, be sure to initialize the data
of addresses F4 to FF to "00".
Initializing method:
Order Page Address Data
1
0
01
2
3
71
3
3
03
4
3
01
5
3
02
6
3
03
7
3
70
8
3
70
9
0
01
6-131
Address F4 to FF
Contents
Procedure
01
01
Press PAUSE (Write) button.
FF
37
Press PAUSE (Write) button.
Check the data changes to
"00".
Check the data changes to
"00".
10
Press PAUSE (Write) button.
Check the data changes to
"11".
00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents