Sony HVR-HD1000J Service Manual page 11

Digital hd video camera recorder
Table of Contents

Advertisement

Ver. 1.3 2008.12
The changed portions from
Ver. 1.2 are shown in blue.
Self-diagnosis Code
Block
Detailed
Function
Code
E
6
1
1
E
6
1
1
E
6
2
0
E
6
2
0
E
6
2
0
E
6
2
0
E
6
2
1
E
6
2
1
E
6
2
1
E
6
2
2
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
Symptom/State
Zoom operations fault.
0
(Cannot initialize zoom lens.)
Focus lens initializing failure and zoom
1
lens initializing failure occur
simultaneously.
Steadyshot function does not work well.
0
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
1
(With yaw angular velocity sensor output
stopped.)
2
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
3
communication abnormality among.
0
Shift lens initializing failure.
1
Shift lens overheating (Pitch).
2
Shift lens overheating (Yaw).
0
Abnormality of thermistor.
Inspect the zoom MR sensor of lens block (Pin w;, wa of CN5301
on the LD-229 board) when zooming is performed when the zoom
switch is operated and the zoom motor drive circuit (IC5404 on
the LD-229 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect pitch angular velocity sensor (SE7202 on the CM-077
board) peripheral circuits.
Inspect yaw angular velocity sensor (SE7201 on the CM-077
board) peripheral circuits.
Refer to [1-6-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred].
Inspect the steadyshot circuit (IC5703 on the LD-229 board).
Refer to [1-6-2. E : 62 : 10 (Shift Lens Initializing Failure)
Occurred].
Refer to [1-6-3. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred].
Refer to [1-6-4. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred].
Refer to [1-6-5. E : 62 : 20 (Abnormality of Thermistor)
Occurred].
1-4
ENGLISH
JAPANESE
ENGLISH
JAPANESE
Correction

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents