Toshiba MMU-AP0072H2UL Service Manual page 110

Multi type
Hide thumbs Also See for MMU-AP0072H2UL:
Table of Contents

Advertisement

No.
Part name
1. Detachment
Fan motor
7
1) Carry out work of Detachment of 2 .
2) Remove the power supply wire and the remote
3) Remove connectors which are connected from the
Ground screw
Cord clamp
NOTE :
Unlock the lock of the housing part and then
remove the connector.
4) Remove the fixing screws "A and B", and then
5) Remove the fan motor lead, TC sensor and TCJ
6) Remove the fixing screws for the fan guard and
Procedure
controller wire from the power supply terminal block
and the remote controller terminal block each.
After then remove the cord clamps (2 positions)
and a screw.
control P.C. board to the other parts and then
remove each wiring from the clamp.
CN510 : Louver motor (20P, White)
CN34 : Float switch (3P, Red)
CN504 : Drain pump (2P, White)
CN100 : TC1 sensor (3P, Blown)
CN101 : TC2 sensor (2P, Black)
CN102 : TCJ sensor (2P, Red)
CN104 : Room temp. Sensor (2P, Orange)
CN333 : Fan motor power supply (5P, White)
CN334 : Fan motor position detection (3P, White)
CN82 : PMV (6P, Blue)
Power supply terminal block
L
L
1
2
remove the electric parts box.
(Fixing screw "A": M4, 0.39"(10 mm), 3 pcs,
Fixing screw "B": M4, 0.31"(8 mm), 1 pc.))
sensor from clamp of the bell mouth.
then hang down it from the clamps.
(M4, 0.39"(10 mm), 5 pcs.))
Ground screw for
shielded wire (system
interconnecting wire)
Remote controller
terminal block
110
Remarks
Fixing screw A
Fixing screw A
Fixing screw A
Electric parts box
Fixing screw B
Fixing screw B
Fixing screw B
Clamp
Clamp
Clamp
Fan motor lead
Fan motor lead
Fan motor lead
TC sensor
TC sensor TCJ sensor
TC sensor TCJ sensor
TCJ sensor
Clam
Clam
Clamp
Clamp
Clamp
p
p
Fan guard
Fan guard
Fan guard
an guard
an guard
ard
ard