National Instruments NI 6115/6120 User Manual page 30

Multifunction i/o devices for pci/pxi/compactpci bus computers
Table of Contents

Advertisement

Chapter 3
Hardware Overview
highValue
Trigger
Figure 3-5. Above-High-Level Analog Triggering Mode
In inside-region analog triggering mode, the trigger is generated when the
signal value is between the lowValue and the highValue, as Figure 3-6
shows.
highValue
lowValue
Trigger
Figure 3-6. Inside-Region Analog Triggering Mode
In high-hysteresis analog triggering mode, the trigger is generated when the
signal value is greater than highValue, with the hysteresis specified by
lowValue, as Figure 3-7 shows.
highValue
lowValue
Trigger
Figure 3-7. High-Hysteresis Analog Triggering Mode
© National Instruments Corporation
3-7
NI 6115/6120 User Manual

Advertisement