Conversion From Ng To Lp - Regency E21-NG10 Owners & Installation Manual

Table of Contents

Advertisement

installation
|
22

Conversion from NG to LP

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
LP Conversion Kit Contains:
Qty. Part #
Description
1
904-163
Burner Orifice #54
1
904-529
5/32" Allen Key
1
918-590
Label "Converted to
LPG"
1
910-582
LP Stepper Motor
1
908-528
Red "LPG" label
1
910-037
L P Injector (Pilot
Orifice)
1
910-233
Thermodisc Switch
1
919-463
Instruction Sheet
Installation of LP Conversion Kit:
1.
Turn the unit off and allow it to cool to
room temperature.
2.
Shut off gas supply and disconnect
power.
3.
Remove safety screen and glass door
(see Door Glass Replacement section in
the manual).
4.
Remove logs and brick panels (if
installed).
5.
Remove the Grate by removing the
screws on each side of the grate.
Remove the 2 screws holding
the grate in position.
6.
Remove the Burner Tray by removing 1
screw on each side of the tray, then slide
the tray to the left and lift out.
Remove the 2 screws,
push Burner Tray to the left, and lift off.
22 |
919-463
Regency
E21-10 Gas Fireplace Insert
®
Conversion from NG to LPG
for E21-10 using SIT 829 NOVA Gas Valve
IF IN DOUBT DO NOT DO THIS CONVERSION !!
7.
Pull off the pilot cap to expose the pilot
orifice.
8.
Unscrew the pilot orifice with the allen
key (provided) and replace with the LP
pilot orifice in the kit.
9.
Remove burner orifice with 1/2" wrench.
Use another wrench to hold onto the
elbow behind the orifice. Replace with the
#54 orifice in the Kit.
Burner
Orifice
10. Remove NG stepper motor by removing
3 screws in locations shown below–re-
place with LP stepper motor, secure in
place with 3 screws.
Remove NG Stepper motor and
replace with LP Stepper motor
11. Remove the switch cover from the left
Remove the 2 nuts holding the switch box in
12. Check for gas leaks with a proper
13. Check for proper spark between the
14. Check pilot flames. Correct flame
15. Check inlet (11" WC min) and outlet
16. Reverse Steps 6 to 3.
17. Attach the label "This unit has been
18. Replace yellow "NG" label with red
19. Check operation of flame control.
20. Check for proper flame appearance
Also check that the pilot and main burner
injectors are appropriate for the gas type.
1
E21-10
side of the body base. Disconnect the
2 wires from the thermodisc and pull
the thermodisc out of the bracket un-
der the left side of the firebox bottom.
Replace with the Thermodisc supplied
with this kit and reconnect the 2 wires.
place, then pull the
thermosdisc out of the bracket.
soapy solution or leak detector.
ignitor and pilot cap. Refer to "Lighting
Procedure" section of the manual for
lighting sequence.
pattern has 3 strong blue flames.
Adjustment can be made by turning
the slotted screw at the top right corner
of the valve. Refer to "Maintenance
Instructions" section of the manual for
correct flame patterns.
(10" WC) pressures. Refer to "Gas
Pipe Pressure Testing" section of the
manual.
converted to LP" near or on top of the
serial number decal.
"LP" label.
and glow on logs.
WARNING!
10.28.14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E21-lp10

Table of Contents