Regency E33-NG10 Owners & Installation Manual

Regency E33-NG10 Owners & Installation Manual

Energy e33 gas insert natural gas propane
Hide thumbs Also See for E33-NG10:
Table of Contents

Advertisement

WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
919-379c
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Energy
MODELS:
E33-NG10 Natural Gas
Owners & Installation Manual
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
E33 Gas Insert
E33-LP10 Propane
03.01.17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E33-NG10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency E33-NG10

  • Page 1 E33 Gas Insert Energy ™ MODELS: E33-NG10 Natural Gas E33-LP10 Propane Owners & Installation Manual WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 The E33 Gas Insert has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The E33-NG10 and E33-LP10 have been approved by Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
  • Page 3: Dimensions

    dimensions UNIT DIMENSIONS LOW PROFILE FACEPLATE 32-1/4 819mm 24-1/2 (622mm) " (83mm) 2 " " (1181mm) (44mm) 16 " (1078mm) (281mm) 4 " (413mm) This appliance does not have the capability to adjust the fan speed using the supplied remote—even though the remote transmitter allows this function.
  • Page 4: Unit Dimensions

    dimensions UNIT DIMENSIONS OPTIONAL VIGNETTE FACEPLATE WITH SPACER E33-10 FPI Direct Vent Gas Insert...
  • Page 5: Unit Dimensions

    dimensions UNIT DIMENSIONS OPTIONAL VIGNETTE FACEPLATE WITHOUT SPACER E33-10 FPI Direct Vent Gas Insert...
  • Page 6: Unit Dimensions

    dimensions UNIT DIMENSIONS OVERSIZE BACKINGPLATE WITH SPACER E33-10 FPI Direct Vent Gas Insert...
  • Page 7: Unit Dimensions

    dimensions UNIT DIMENSIONS OPTIONAL 4 SIDED VIGNETTE FACEPLATE 4 SIDED VIGNETTE FACEPLATE E33-10 FPI Direct Vent Gas Insert...
  • Page 8: Table Of Contents

    table of contents Dimensions Optional vignette inlay installation .......26 Optional hearth trim installation- vignette faceplate with Unit dimensions .............3 Spacer and low profile faceplate .........28 Low Profile Faceplate ............3 Optional hearth trim installation- Unit dimensions .............4 Vignette faceplate without spacer .......29 Optional vignette faceplate with spacer ......4 Optional hearth trim installation- Low profile ....30 Unit dimensions .............5...
  • Page 9: Copy Of Safety Label

    Ensure that the safety label is attached to the unit. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 10: Ma Code - Co Detector

    requirements MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 11: Important Message

    2) Installation and repair should be done by a CIALLY THE FIREPLACE GLASS, AND qualified service person. SHOULD STAY AWAY TO AVOID BURNS The Regency Gas Insert must be installed in OR CLOTHING IGNITION. 3) The appliance should be inspected before use accordance with these instructions. Carefully read and at least annually by a professional service all the instructions in this manual first.
  • Page 12: Specifications

    Standard Flush Door Propane 35,500 Btu/h e. Remote Control The Regency Gas Insert is installed as listed below. Min. Input: Natural Gas 20,000 Btu/h 1) Check all clearances to combustibles. Refer 10) Final check. Refer to the "Operating...
  • Page 13: Gas Pressure Testing

    installation GAS PRESSURE FACTORY-BUILT (METAL) WOOD- BURNING FIREPLACE TESTING REQUIREMENTS The appliance must be isolated from the gas sup- ply piping system by closing its individual manual NOTE: Any parts that are removed must be removed shut off valve during any pressure testing of the in a way that would allow them to be re-installed if the insert is ever removed (removal of rivets or gas supply piping system at test pressures equal...
  • Page 14: Minimum Fireplace Opening

    MINIMUM FIREPLACE OPENING The minimum fireplace opening for the Regency gas fireplace insert is shown in the following diagram and the table: Front Depth Max Lintel Bar Depth Height Depth Width (Rear) Width (Front) Width Prior to Taper Low Profile Faceplate 8"...
  • Page 15: Combustible Mantel Clearances

    installation MINIMUM CLEARANCES TO COMBUSTIBLES From Unit Side Walls * A 8" (203 mm) Ceiling B 47" (1194 mm) Min. Mantel Height C 15" (381 mm) Max. Mantel Depth D 12" (305 mm) Alcove Width E 76" (1930 mm) Alcove Depth 36"...
  • Page 16: Gas Connection

    Part # Description 948-305 3" Flex - 35 ft. 946-529 Regency Co-linear DV Vertical Termination Cap Alternate Approved Caps 46dva-VC Vertical Termination Cap 46dva-VCH High Wind Cap 46dva-GK 3" Co-linear Adaptor with flashing...
  • Page 17: Remote Receiver Installation

    2) Loosen the "IN" and/or "OUT" pressure tap(s), Note: Aeration Adjustment should only be turning counterclockwise with a 1/8" wide flat performed by an authorized Regency screwdriver. Installer at the time of installation. 3) Attach manometer to "IN" and/or "OUT"...
  • Page 18: Optional Brick Panel

    installation 7) Insert the back panel by sliding it between the OPTIONAL 4) Remove the two screws from the bottom of sidewalls of the firebox and the rear log support. the baffle plate. Install the bottom clips onto BRICK PANEL the baffle plate (refer to Diagram 1).
  • Page 19: Log Set Installation

    DIRECT VENT FIREPLACE installation LOG SET INSTALLATION LOG INSTALLATION WARNING: 3) Remove the grate by removing the two Phillips Dangerous operating conditions may occur if these screws. Slide the grate outwards to remove it from logs are not positioned in their correct certifi ed loca- the unit (refer to Diagram 1).
  • Page 20 DIRECT VENT FIREPLACE installation 7) Align the bottom grooves of log 03-21 onto the right side of the grate and gently slide the log back until it touches the locating tab (refer to Diagram 4 & 5). 03-23 03-21 03-21 03-17 Locating Diagram 7...
  • Page 21 DIRECT VENT FIREPLACE installation 12) Place log 03-19 over the left center of the grate. Ensure the log set looks like Diagram 12. 03-23 03-18 03-22 03-20 03-17 Diagram 10 03-19 Diagram 12 11) Place log 03-24 over log 03-23 and log 03-21 ensuring the pin hole of log 03-24 lines up with the right pin of log 03-23 and the right pin of log 03-21 13) Separate platinum embers and place at the front...
  • Page 22: Conversion Kit 342-969 From Ng To Lp

    E33-10 installation Conversion from NG to LP CONVERSION KIT 342-969 FROM NG TO LP for E33-10 using SIT 829 NOVA Gas Valve for E33-10 using SIT 829 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 6. Unscrew the pilot orifice with the 5/32"...
  • Page 23: Optional Vignette Faceplate Installation

    installation E33-10 OPTIONAL VIGNETTE FACEPLATE INSTALLATION OPTIONAL VIGNETTE FACEPLATE INSTALLATION 1. Install the lower trim to the unit with 2 screws on each side as shown in the drawing below. 4. Tuck the wires into the silver box and secure them with a small grommet.
  • Page 24: Spacer Installation For 3 Sided Vignette Faceplate

    installation E33-10 SPACER INSTALLATION FOR 3 SIDED VIGNETTE FACEPLATE SPACER INSTALLATION FOR 3 SIDED VIGNETTE FACEPLATE 3. Finally, attach the spacer to vignette faceplate (vignette NOTE: faceplate is purchased separately) with 2 side screws • A spacer can be ordered, if required. on the top (1 per side).
  • Page 25: Oversize Backing Plate Installation

    installation E33-10 OVERSIZE BACKING PLATE INSTALLATION OVERSIZE BACKINGPLATE INSTALLATION OVERSIZE BACKING PLATE INSTALLATION OVERSIZE BACKING PLATE INSTALLATION WITH WITHOUT SPACER SPACER Oversize backing plate can be ordered for the unit 1) Install the spacer to the back of the faceplate backing with 6 if required.
  • Page 26: Optional Vignette Inlay Installation

    installation OPTIONAL VIGNETTE INLAY INSTALLATION OPTIONAL VIGNETTE INLAY INSTALLATION 1. Remove 5 screws from the backside of the Vignette frame cover 3. Place the Inlay on the Front Trim Assembly. and keep them aside (3 at bottom and 2 at top). Vignette Frame Vignette Frame Cover 2.
  • Page 27 installation E33-10 6. Reverse step1. 5. With the Inlay in position, place the mesh screen over the inlay. NOTE: The flush side of the mesh screen should face the inlay. 7. Install the Vignette frame with Inlay onto the 2 hooks provided on the unit.
  • Page 28: Optional Hearth Trim Installation- Vignette Faceplate With Spacer And Low Profile Faceplate

    installation LRI4E/HRI4E/LRI6E/HRI6E/E33 OPTIONAL HEARTH TRIM INSTALLATION- VIGNETTE FACEPLATE WITH SPACER AND LOW OPTIONAL HEARTH TRIM INSTALLATION - PROFILE FACEPLATE VIGNETTE FACEPLATE WITH SPACER AND LOW PROFILE FACEPLATE Customizing the Hearth Trim: 5) Secure the hearth trim with a clip on its side to keep it steady as shown in the diagram below . The Hearth Trim can be adjusted to custom fit an installation by pulling apart the top piece from the bottom piece. Minimum height of the hearth trim is 2” and can be adjusted up to maximum 6”. 1) Cut the top of the bottom piece of the hearth trim to the appropriate height using a metal cutting blade. Clip - secures hearth trim NOTE: The tab bends at the back of the top piece of the hearth trim should be used as the measuring point to the hearth to measure the...
  • Page 29: Optional Hearth Trim Installation

    LRI4E/HRI4E/LRI6E/HRI6E/E33 installation OPTIONAL HEARTH TRIM OPTIONAL HEARTH TRIM INSTALLATION- VIGNETTE FACEPLATE WITHOUT SPACER INSTALLATION - VIGNETTE FACEPLATE WITHOUT SPACER Customizing the Hearth Trim The Hearth Trim can be adjusted to custom fit an installation by pulling apart the top piece from the bottom piece. Minimum height of the hearth trim is 2” and can be adjusted up to maximum 6”. 1. Discard the spacer brackets, as these are not required when installing the unit without spacer. 2. Cut the top of the bottom piece of the hearth trim to the appropriate height using a metal cutting blade.
  • Page 30: Optional Hearth Trim Installation- Low Profile

    installation E33-10 OPTIONAL HEARTH TRIM INSTALLATION- LOW PROFILE OPTIONAL HEARTH TRIM INSTALLATION- LOW PROFILE If you do not have spacer, remove the spacer brackets from the heart trim by removing 3 screws per side. Refer to diagrams 1 and 2 below. Diagram 1-Top View Spacer Brackets Front...
  • Page 31: Safety Screen Installation / Removal - Low Profile Faceplate

    installation SAFETY SCREEN INSTALLATION / REMOVAL - LOW PROFILE FACEPLATE 1. To remove safety screen, flip open bottom louver and remove 2 screws 2. Pull off safety screen and frame from glass door. in locations shown below. 3. To install, reverse Steps 2-1. STANDARD FLUSH DOOR REMOVAL / INSTALLATION NOTE: See Vignette or Low Profile Faceplate instructions for removal of screen prior to removing glass.
  • Page 32: Wiring Diagram

    18 GA. 20 Ft. installed on an interior wall. to 120V wire. 20 GA. 12 Ft. Regency offers an optional programmable ® 22 GA. 9 Ft. thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or NOTE: When the wall thermostat is connected, the remote control transmitter UL approved may be used.
  • Page 33: First Fire

    operating instructions FIRST FIRE 8) The unit should never be turned off, and on again without a minimum of a 60 second wait. 5. Press and release the ON/OFF button on the remote handheld transmitter. An audible beep The first fire in your stove is part of the paint curing 9) Hook up remote receiver to wire marked 'receiver' should be heard from the receiver.
  • Page 34: Copy Of Lighting Instruction Plate

    Blower: QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ : Regency gas appliances use high tech blowers • Ne tentez pas d’allumer d’appareil to push heated air farther into the room. It is not •...
  • Page 35: Maintenance

    (not with wall paint). under water. Immediately call a qualified 3) Check for evidences of excessive Regency uses StoveBrite Paint - Metallic service technician to inspect the appliance condensation, such as water droplets forming Black #6309.
  • Page 36: Door Glass

    When removing side brick panels the two screws purchase your replacement from an authorized that hold the grate down must be removed first. Regency dealer only, do not use substitute materials. Follow our step-by-step instructions for replacement. 9) Remove the 12 screws holding the Access Warning: Wear gloves when removing damaged Panel in place.
  • Page 37: Valve Assembly Removal And Installation

    maintenance 7) When removing base brick sides the two screws 12) Pull Fan Assembly forward, to disengage the fan that hold the grate down must be removed first. clip on the rear wall. Then lift the Fan Assembly 11) Disconnect the inlet gas line. up and pull through firebox opening.
  • Page 38: Parts

    parts list MAIN ASSEMBLY Part # Description 1) 340-038 Fan Access Plate 2) 340-103 Gasket - Fan Access Plate 3) 320-517/P Fan Assembly 120 V 910-331/P Fan Motor 120 V 5) 910-750 Power Cord 910-752 Wire Harness (Faceplate) 7) 910-142 Fan Auto On/Off Thermodisc 8) * Thermodisc Bracket...
  • Page 39: Burner & Log Assembly

    parts list BURNER & LOG ASSEMBLY Part # Description 52) 340-104 Gasket - Valve Tray 342-574/P Valve Assembly - NG 342-576/P Valve Assembly - LP 57) 910-578 Valve - S.I.T. - Natural Gas 910-580 Valve - S.I.T. - Propane 59) * Valve Tray 66) 910-038/P Pilot Assy-3 Flame-S.I.T.-NG...
  • Page 40: Vignette Faceplate

    parts list VIGNETTE FACEPLATE Part # Description 342-957 Oversize Backing Plate 342-924 Faceplate Low Profile Mt. Black 342-954 Backing Plate Custom 3-Sided 342-934 Faceplate Vignette 4 sided.Mt. Black 342-914 Faceplate Vignette Mt. Black Vignette 342-934 Faceplate Vignette 4 sided Mt. Black 342-959 Backing Plate Custom 4 Sided 342-958...
  • Page 41 notes E33-10 FPI Direct Vent Gas Insert...
  • Page 42: Warranty

    FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: December 2016 Regency Gas Products Warranty 42 | E33-10 FPI Direct Vent Gas Insert...
  • Page 43 Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: December 2016 Regency Gas Products Warranty E33-10 FPI Direct Vent Gas Insert...
  • Page 44 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 45 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 48 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency and Energy are trademarks of Fireplace Products International Ltd. © Copyright 2016,Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

E33-lp10

Table of Contents