Chapter 7
Analog Output
Analog Output Digital Triggering
Connecting Analog Output Signals
NI USB-621x User Manual
the buffer at a fast enough rate to keep up with the generation, the buffer
will underflow and cause an error.
Analog output supports two different triggering actions:
•
Start trigger
•
Pause trigger
A digital trigger can initiate these actions on the USB-621x devices. Refer
to the
AO Start Trigger Signal
more information about these triggering actions.
AO <0..1> are the voltage output signals for AO channels 0 and 1.
AO GND is the ground reference for AO <0..1>.
Figure 7-2 shows how to make AO connections to the device.
+
V OUT
Load
–
AO GND
–
Load
V OUT
+
Figure 7-2. Analog Output Connections
and
AO Pause Trigger Signal
Analog Output Channels
AO 0
Channel 0
AO 1
Channel 1
M Series Device
7-4
sections for
Isolation
Barrier
(USB-6215
and USB-6218
devices only)
Digital
Isolators
ni.com