National Instruments NI USB-621x User Manual page 146

Bus-powered m series usb devices
Hide thumbs Also See for NI USB-621x:
Table of Contents

Advertisement

Appendix B
Troubleshooting
NI USB-621x User Manual
are various methods of achieving this reference while maintaining a high
common-mode rejection ratio (CMRR). These methods are outlined in
Chapter 5,
Connecting AI Signals on the USB-6210/6211 Devices
Chapter 6,
Connecting AI Signals on the USB-6215/6218
AI GND is an AI common signal that routes directly to the ground
connection point on the devices. You can use this signal if you need a
general analog ground connection point to the device. Refer to the
Use Differential Connections with Ground-Referenced Signal Sources
section of Chapter 5,
Devices, for more information.
How can I use the AI Sample Clock and AI Convert Clock signals on
an M Series device to sample the AI channel(s)?
M Series devices use ai/SampleClock and ai/ConvertClock to perform
interval sampling. As Figure B-1 shows, ai/SampleClock controls the
sample period, which is determined by the following equation:
Channel 0
Channel 1
Figure B-1. ai/SampleClock and ai/ConvertClock
ai/ConvertClock controls the convert period, which is determined by the
following equation:
This method allows multiple channels to be sampled relatively quickly in
relationship to the overall sample rate, providing a nearly simultaneous
effect with a fixed delay between channels.
Connecting AI Signals on the USB-6210/6211
1/sample period = sample rate
Convert Period
Sample Period
1/convert period = convert rate
B-2
and
Devices.
When to
ni.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ni usb-621 series