Other Counter Features; Sample Clock - National Instruments NI USB-621x User Manual

Bus-powered m series usb devices
Hide thumbs Also See for NI USB-621x:
Table of Contents

Advertisement

Chapter 9
Counters

Other Counter Features

Sample Clock

GATE
SOURCE
COUNTER VALUE
SAMPLE CLOCK
BUFFER
TIME N
NI USB-621x User Manual
the signal goes high or vice versa. For continuous pulse generations, the
counter stops generating pulses while the external trigger signal is low and
resumes when the signal goes high or vice versa.
When using a pause trigger, the pause trigger source is routed to the
Counter n Gate signal input of the counter.
When taking counter measurements, you can enable a sample clock. When
you use a sample clock, measurements are saved after an active edge of the
sample clock. Figure 9-29 shows an example of using a sample clock with
a buffered period measurement. In this example, a period is defined by two
consecutive rising edges of the Gate.
Counter Armed
1
t
t
0
1
2
3
4
1
4
4
t
t
2
3
Figure 9-29. Sample Clock Example
9-32
2
1
2
3
4
3
t
t
4
5
1
ni.com