CHARGING SYSTEM
-
Atternator
cH-13
Brushes
1.
MEASURE EXPOSED BRUSH LENGTH
Minimum exposed
length:
1.5 mm
(O.O59 in.)
lf
the
brush length
is
less
than minimum,
replace the
brushes.
2.
IF NECESSARY, REPLACE BRUSHES
(a)
Unsolder and remove the brush and spring.
(b)
Run
the wire of the brush through the hole in
the
brush holder, and insert the spring
anO
Orusn
inio ine
brush holder.
1O.5
mm
(0.413
in.
cHo414
Ohmmeter
Ohmmeter
(c)
Solder
the
brush
wire to the
brush
holder
exposed length.
Exposed
length:
1O.S
mm (0.413 in.)
(d)
Check
that the brush
moves smoothly
in the
brush
holder.
(e)
Cut off the
excess
wire.
(f)
Apply insulation paint to the soldered point.
Rectifier
1.
INSPECT POSITIVE SIDE RECTIFIER
(a)
Using an ohmmeter, connect one tester prove
to the
positive stud and the other to each rectifier
t"rrin"i.
(b)
Reverse
the polarity of the tester
probes.
(c)
Check
that one shows continuity and the other shows
no continuity.
lf
not, replace the rectifier holder.