Technical Data

Dimensions
Power supply
Radio frequency
Radio signal range
Temperature range
Ambient operating temperature
Humidity operating range
Class of operation
Degrees of protection
Control Accuracy
Battery life (with alkaline batteries)
Battery back up time and date
Shortest switching period
Hot water pre-heat settings
Central heating settings
Energy Class
Pollution Class
Software Class
Ball pressure test
Relevant EC Directives:
2006/95/EC Low Voltage Directive
2004/108/EC Electromagnetic Compatibility Directive
1999/5/EC R&TTE Directive
2006/66/EC Battery Directive
2011/65/EU RoHS Directive
Applied Standards:
EN60730-1; EN60730-2-7; EN60730-2-9
EN 300 220-2; EN 301 489-3
2
Digistat +2RF Transmitter
Thermostat
137mm x 96.5mm x 31.3mm
2xAA 1.5V alkaline batteries
433 MHz
30m typically. The range may be affected by the composition / density and
number of walls between the Digistat+2RF and LP10RF.
5°C to 32°C
0°C to +40°C
25 - 90% non condensing up to
45°C
--
IP30
+0.5°C @ 20°C
approx. 2 years
10 years min.
1 minute
--
6 per day
IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
2
A
90°C
Pack Contents:
LP10RF Programmer / RF receiver
Digistat+2RF transmitter
Screws (x2)
Wall Plugs (x2)
Instructions
Batteries (x2) AA Alkaline
LP10RF Receiver
--
24Vd.c. less than 65mA
433 MHz
--
0°C to +50°C
30 - 95% non condensing up to 45°C
II
IP24
Better than ±1 second per day @
25°C
N/A
10 years min.
1 minute
3 ON / 3 OFF
--
2
A
90°C