Option 01 - How to change from 24hr to
12hr clock
Enter user options, select option 01 and use + and – keys
to select desired option, 12 = 12hr and 24 = 24hr. Press
3. Once the temperature has
to accept change.
or
Option 02 - How to change to another
predefined program 1, 2 or 3
Enter user options, select option 02 and use + and – keys
to select desired program 1, 2 or 3. 1 = program 1, 2 =
Congratulations!
program 2 and 3 = program 3. Press
4. To exit press
desired change.
Pre-set Programs 2 and 3 are shown below:
Pre-set Program 2 (Home for Lunch)
Event
1
Time
6:30
To change temperature for a short period (Override):
Temp
21.0
1. Press + or - buttons to
NOTE:
4
5
The above settings can be understood using the
6
14:00
16:30
22:30
chart to the right.
16.0
21.0
7.0
2. After 5 seconds will start
16
3. To exit override press
5
6
once, the display
C)
0
What is it
Change 12h or 24h clock
Change to another pre-set
programme
Change the number of
programme events per day
Switch on/off automatic
summer/winter time change
Adjust date and time
Change temperature offset °C
Restore pre-set programme
To disable Off function
press
to confirm and
use the + or – button to
Access protection lock
adjust required temperature
(temperature shown flashing)
been set press
to
confirm and move to the next
time and temperature periods
to be adjusted confirming
changes by pressing
button. (max 6 periods).
or
until you return to auto
mode with the bottom arrow
pointing to auto (as shown).
Congratulations!
The unit is now set correctly to follow your required timings.
2
3
4
8:30
12:00
14:00
16:30
16.0
21.0
16.0
21.0
adjust set temperature. Set
temperature shown flashing
controlling at selected set
point but displays actual room
temperature. 2 chrevons
indicates override mode.
once or wait until next change
in the pre-set program.
Min
12
1
2, 4 or 6
On
-5
On
On
On
(* small 1 in lower half of screen
25
°C
shows which time period is being set
e.g. 1=1st period, 2 = 2nd period etc)
20
°C
15
°C
10
°C
5
°C
to accept
As you can see, at 06:30, the heating will come on to
raise the temperature to 21°C.
At 08:30, the temperature set point is dropped to 16°C,
it stays at 16°C until 12:00 when the heating comes on to
raise the temperature to 21°C. The temperature stays
at 21°C until 14:00 when it drops to 16°C. At 16:30, the
5
6
heating comes on to raise the temperature to 21°C where
it stays until 22:30, when the temperature drops down
22:30
to a setback temperature of 10°C until 06:30, when the
cycle repeats the next day.
10.0
DIGISTAT+2RF Room Thermostat
Max
Default
24
24
3
1
6
Off
On
Factory Set
5
0
Off
Off
Off
On
Off
Off
1
2
3
4
06:30 08:30 12:00 14:00 16:30 22:30
Time Period
Installation & User Guide
5
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Digistat+2rf

Table of Contents