20 | Admission / exhaustion accessories (accessory Ø 80/80 mm)

6.2 Fitting instructions

• The permissible maximum ue/a
various possible ue con guratio
starting on chapter 8.6.
• If the concentric ue/air pipe enters a chimney below
ground level, the appliance may register a fault and shut
down in cold weather due to ice formation. For that reason
such ue con gurations should be avoided.
6.3 Explanation of Symbols on Fitting Diagrams
Lightly grease seal on ue side with solvent-free
grease (e.g. Vaseline) (Fig. 29).
Push ue kit fully home (in this case: 50 mm
50
insertion depth) (Fig. 30).
2x
Drill two 3-mm diameter holes in the combus-
tion air pipe. Maximum drilling depth 8 mm. It is
Ø 3mm
essential that ue pipe is not damaged!
Fig. 31).
2x
Secure joint with the screws supplied (Fig. 32).
Fig. 29
6 720 800 095 (2014/05)
ir pipe length, Lmax, for the
ns is speci ed in the tables
360°
6 720 604 873-17.1O
50
Fig. 30
2x
Ø 3mm
Ø 3mm
Fig. 31
2x
Fig. 32
50
6 720 604 873-18.1O
Ø 3mm
6 720 604 873-21.1O
6 720 604 873-22.1O