Intake
1
Straight section length
2
90° elbows (qty)
3
45° elbows (qty)
4
30° elbows (qty)
5
S
b u
t -
t o
: l a
6
Total equivalent vent length=
Table 19
Note: Do not count terminals and rst elbow used on intake and
exhaust.
Total maximum length for separate tubes
(exhaust/admission) must not exceed 16
meters.
8.6.2 Adjusting fan speed
After obtaining the total sum of the conducts, proceed as
follow:
Press ON/OFF button into OFF.
Press and hold "Program" button and press ON/OFF button
to turn appliance ON (see Fig. 47 ).
Fig. 47
As soon as '188' is displa y ed, release "Program" button
, and the display should read P2.
Press one time
to access the program P2. In the LCD
display is visible the attributed value (factory value: GN: 8,
LPG:7).
Press
or
to choose the fan speed suitable with
your installation, see tab.20 for separate tubes admission/
exhaust Ø 80/80 mm.
Press and hold ( 5 sec.) "Program" button
display ashes.
Selected valu e is memorized.
Therm 6000S
_4_ x 1=
4
_1_ x 1 =
1
_0_ x 0.5 =
0
_0_ x 0.4 =
0
5
12
until the
Fan speed for separate tubes Ø80/80 mm
Mode
Conduct length
P2
From 1 m until 6 m
from 6.1 m until 14 m
from 14.1m until 16 m
Table 20
1) Total conducts lengths of Table 17. Do not count with the
rst elbow and the accessory of wind/rain protection.
Do not set P2 to greater then 10.