CVP09FX

[3] FUNCTION

1. Cool Operation
In the "COOL" mode, the thermostat circuit is controlled by 3 thermo-
stat lines(C1~C3).
When the difference between Room Temperature and Preset Temper-
ature is in [2]~[4] area, compressor is driving or starts driving. If [1]
area is detected, compressor will stop. And indoor fan speed is set as
following speed.
Room Temperature—Preset Temperature
C1
0.9 / 2.7°F
C2
0 / 0.9°F
C3
-2.7 / -0.9°F
Room Temperature - Preset Temperature
C1
C2
C3
Indoor fan speed
Customer Setting
Area
L
M
H
[4]
[3]
CL
CM
CH
[2]
[1]
2. Dehumidification Operation
In the "Dehumidification" Mode, compressor is controlled by room tem-
perature. If it goes over D1 line and gets into the area [3], or if it lowers
than D2 line and gets into the area [1], compressor will stop.
If the evaporator temperature is lower than D3 line, indoor fan speed
will be DH and if the evaporator temperature is higher than D3 line,
indoor fan speed will be DL when the room temperature is in area [2].
Room Temperature
D1
111.2 / 113.0°F
D2
50.0 / 51.8°F
Room Temperature
D1
D2
[4]
[3]
[2]
[1]
AUTO
CAH
CM
CAL
[3]
[2]
[1]
Indoor fan speed
Evaporator Temperature
Lower than D3
Higher than D3
D3
53.6 / 60.8°F
Evaporator Temperature
D3
3. Fan Operation
In the "Fan" mode, compressor and outdoor fan doesn't operate.
Indoor fan motor operates as follows.
Indoor fan speed
Customer Setting
L
M
H
AL
AM
AH
4. Ventilating Operation
In the "Ventilation" mode, compressor and indoor fan doesn't operate.
Outdoor fan motor operates as follows.
Indoor fan speed
Customer Setting
L
M
600[rpm]
900[rpm]
5. Indoor Fan Speed
Fan speeds are given by the indoor fan motor, "DL"~"AH" which are
available in the following operation mode.
In the "COOL" or "DRY" mode, indoor fan speed is different by con-
denser temperature.
Fan Speed
DL
DEHUM
DH
CL
COOL SOFT
CAL
WET
COOL
CM
COOL LOW
CAH
CH
COOL HIGH
AL
FAN ONLY
FAN ONLY
AM
FAN ONLY
AH
FAN ONLY
6. Overheating protection system
If the condenser temperature goes over 136.4°F during the cooling or
dry operation, outdoor fan speed will rise to prevent the overloading of
the compressor and restrain the rise in high pressure, and If it lowers
than 134.6°F, outdoor fan speed will return.
If the condenser temperature goes over 158.0°F during the cooling or
dry operation, compressor will stop and if it lowers than 149.0°F, com-
pressor will restart after 3 minutes.
4 – 3
Customer Setting
AUTO
DH
DL
H
1200[rpm]
Setting
[rpm]
-
AUTO
400 ~ 500
-
AUTO
500 ~ 600
-
420 ~ 520
-
AUTO
500 ~ 600
-
-
570 ~ 670
AUTO
570 ~ 670
-
AUTO
650 ~ 750
-
720 ~ 820
-
520
-
640
-
750