FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES
Self diagnostic}
display
Detection
Restart
Restart | Indoor| Outdoo
time
condition
times
Indoor fan
Stops operation if no revolution pulse
When indoor
Operation OFF
No limit
| Yes | No
lock
signal is input from the indoor fan motor for} fan is revolving
one minute.
Indoor fan
Stops operation if the revolution pulse
rpm error
signal from the indoor fan indicates low
rpm (approximately 300 rpm or less).
During cooling
| Automatically
No limit
No
restarts when the
exchange
temperature rises
above the freezing
prevention
temperature (above
2°C)
and dry
Automatically
No limit
Yes | Yes
8times
Operation
Function
Description
Indoor
freezing
guard
Lowers the operating frequency if the
temperature of the indoor heat exchanger
goes below 5°C during cooling. Stops the
compressor if the temperature stays below
0°C for 4 minutes.
Indoor
Lowers the operating frequency if the
During heating
overheating
| temperature of the indoor heat exchanger
restarts when the
control
rises above the overheating temperature
exchange
during heating. Stops the compressor if the
temperature goes
temperature stays above the overheating
below the
temperature for 1 minute at minimum
overheating
frequency or less.
temperature.
Set values for overheating temperature
During normal operation: 45°C to 54°C
During full power operation: 47°C to
58°C
DC
overcurrent
Automatically
restarts after safety
time (170 seconds)
Stops the compressor if a current of
approximately 23A or more flows in the
power transistor module.
During
compressor
operation
Yes |} Yes
AC
overcurrent
Automatically
4 times
restarts after safety
time (170 seconds)
Lowers the operating frequency if the
compressor AC current exceeds
set value(s ).Show "2-2(1)AC peak control"
Stops the compressor if the current
exceeds at 40Hz or less set value(x ).
During
compressor
operation
Lowers the operating frequency if the
No limit
temperature of the compressor chamber
thermistor (TH1) rises above 105°C.
Stops the compressor if the thermistor
stays above 105°C for 1 minutes at
minimum frequency or less.
During
compressor
operation
Automatically
restarts after safety
time (170 seconds)
Compressor
overheating
control
Compressor | Stops the compressor ifthe compressor
| During
Automatically
4 times
high
chamber thermistor is above 114°C.
operation
restarts when
temperature | (Or when TH1 shorts)
thermistor (TH1)
error
temperature falls
below 100°C
(approximately 30
minutes)
| Model | AE-X08CR
AE-X10CR
AE-X13CR
AU-X08CR
AU-X10CR
AU-X13CR
Set | Cool | _5.3A