New Refrigerant : R-410A
SPECIFICATIONS ............................................................................................................................................. 2
EXTERNAL DIMENSIONS ................................................................................................................................. 4
WIRING DIAGRAMS ......................................................................................................................................... 6
ELECTRICAL PARTS ......................................................................................................................................... 9
BLOCK DIAGRAM ............................................................................................................................................ 10
MICROCOMPUTER CONTROL SYSTEM ....................................................................................................... 12
FUNCTIONS .................................................................................................................................................... 19
FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES ............................................................... 25
BREAKDOWN DIAGNOSIS PROCEDURE .................................................................................................... 29
REFRIGERATION CYCLE ............................................................................................................................. 29
PERFORMANCE CURVES ............................................................................................................................. 31
DISASSEMBLING PROCEDURE .................................................................................................................... 33
OPTION ........................................................................................................................................................... 40
REFRIGERANT PIPING INSTALLATION/SERVICE MANUAL FOR AIR CONDITIONERS USING R-410A .. 41
SERVICE MANUAL
ROOM AIR CONDITIONERS
INDOOR UNIT
AH-X08CR/10CR/13CR
AY-X08CR/10CR/13CR
OUTDOOR UNIT
AU-X08CR/10CR/13CR
AE-X08CR/10CR/13CR
MODELS
In the interests of user-safety (Required by safety regulations in some
countries) the set should be restored to its original condition and only
parts identical to those specified should be used.
TABLE OF CONTENTS
SHARP CORPORATION
1
SPLIT TYPE
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
S32//AYX13CR/
Page

Advertisement

Table of Contents
loading

Summary of Contents for Sharp AH-X08CR

  • Page 1 AH/AY-X10CR AH/AY-X13CR SERVICE MANUAL S32//AYX13CR/ SPLIT TYPE ROOM AIR CONDITIONERS INDOOR UNIT AH-X08CR/10CR/13CR AY-X08CR/10CR/13CR OUTDOOR UNIT AU-X08CR/10CR/13CR AE-X08CR/10CR/13CR MODELS In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
  • Page 2 AH/AY-X10CR AH/AY-X13CR SPECIFICATIONS INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT MODEL ITEMS AH-X08CR AU-X08CR AH-X10CR AU-X10CR AH-X13CR AU-X13CR 2.2(0.9 _ 2.7) 2.8(0.9 _ 3.3) 3.6(0.9 _ 4.0) Cooling capacity(Min. ~ Max.) kW Moisture removal Liters/h...
  • Page 3 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT MODEL ITEMS AY-X08CR AE-X08CR AY-X10CR AE-X10CR AY-X13CR AE-X13CR 2.2(0.9 _ 2.7) 2.8(0.9 _ 3.3) 3.6(0.9 _ 4.0) Cooling capacity(Min. ~ Max.) kW 3.2(0.9 _ 3.6) 3.7(0.9 _ 5.0) 4.8(1.0 _ 6.2) Heating capacity(Min.
  • Page 4 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR EXTERNAL DIMENSIONS 18.5 Length unit (mm) INVERTER AIR CONDITIONER Remote controller Figure E-1. INDOOR UNIT 37.5 179.5 182.5 Figure E-2. OUTDOOR UNIT...
  • Page 5 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR 815 (unit size) Ceiling More than 50mm Center of wall hole: Leftward piping Center of wall hole: Backward piping Outline of indoor unit Figure E-3. INSTALLATION DIMENSIONS...
  • Page 6 Open circuit of serial signal line Short circuit of serial signal line Abnormal fan motor of indoor unit <Indication of the abnormal condition> LED indicator will blink,if the set CB612-2 is in abnormal condition. Figure W-1. Wiring Diagram for AH-X08CR/X10CR/X13CR and AY-X08CR/X10CR/X13CR...
  • Page 7 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR...
  • Page 8 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR...
  • Page 9 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR...
  • Page 10 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR...
  • Page 11 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR ELECTRICAL PARTS For Model AH-X08CR/X10CR/X13CR, AY-X08CR/X10CR/X13CR DESCRIPTION MODEL REMARKS SITE Indoor fan motor ML-A915 220 - 240V, 50Hz AH, AY Indoor fan motor capacitor – 430V, 2µF AH, AY Transformer – Primary; AC 220 - 240V, 50Hz AH, AY Secondary;...
  • Page 12 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR BLOCK DIAGRAMS INDOOR UNIT DC power supply circuit AC power Fan motor phase control circuit Room fan motor WPE1 Rotation pulse input circuit Fan motor pulse detect AC clock circuit Louvre motor drive circuit(upper) Flow direction control (louver motor upper) Louvre motor drive circuit(lower) Flow direction control (louver motor lower) Remote controller signal reception circuit...
  • Page 13 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR OUTDOOR UNIT for AU-X08CR/X10CR and AE-X08CR/X10CR 15 A protection Unit-unit wiring (AC power Power supply circuit Smoothing Active filter Filter circuit circuit circuit and serial signals) CPU oscillator circuit DC overvoltage detection circuit protection Outdoor fan Outdoor fan relay drive circuit 4-way valve(except for 4-way valve relay drive circuit 15 A...
  • Page 14 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR MICROCOMPUTER CONTROL SYSTEM...
  • Page 15 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR FUNCTIONS Cooling Heating AH-X08CR/X10CR/X13CRare not provided with the Room Frequency Room Frequency Room Frequency heating function. temp. Code temp. Code temp. Code zone zone zone 1. INDOOR UNIT (Hot keep fan) 1-1 Temperature Adjustment a. Normal control...
  • Page 16 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR (1) Control for indoor freezing prevention If the temperature of the indoor heat exchanger stays below approximately 0°C for four minutes during cooling or dry, this control stops the compressor. Over 2˚C the compressor will run again. (2) Control for cold air blowing prevention When heating begins, this control stops the indoor fan until the temperature of the indoor heat exchanger...
  • Page 17 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR compressor chamber temperature rises above 25°C. 1-6 OFF-timer Preheat does not operate for 2 hours after heating The OFF-timer is set by pressing the OFF-timer is stopped. After that, it goes on for 180 minutes button. Operation is as follows: and then stops for 30 minutes, repeatedly.
  • Page 18 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR informed by the flashing number as well as the 1-15 Auto Restart lighting pattern of the operation lamp which When power failure occures, after power is flashes with the timer lamp.(For details, refer to recovered, the unit will automatically restart in the Error diagnostic method.) same setting which were active before the power failure.
  • Page 19 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR 2-2 Frequency control (1) AC current peak control S e t v a l v e M o d e l C o o l H e a t A E - X 0 8 C R 7 .
  • Page 20 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR 2-3 Overcurrent protection (1) DC overcurrent detection, AC overcurrent detection To protect against overcurrent due to sudden changes in load, the compressor is stopped if the set value AC : 12.5A) is exceeded in the AC section. In this case, the outdoor fan does not stop, and 170 seconds after operation is stopped, another try will be made.
  • Page 21 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES Operation Self diagnostic display Function Description Detection Restart Restart Indoor Outdoor time condition times Indoor fan Stops operation if no revolution pulse When indoor Operation OFF No limit lock signal is input from the indoor fan motor for fan is revolving one minute.
  • Page 22 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR Operation Self diagnostic display Function Description Detection Restart Restart Indoor Outdoor time condition times Outdoor heat Lowers the operating frequency if the During Automatically No limit exchanger temperature of the outdoor heat exchanger compressor restarts after safety overheating rises above 56°C during cooling.
  • Page 23 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR...
  • Page 24 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR...
  • Page 25 Evaporator Flare coupling Flare coupling 3-way 2-way valve valve Outdoor unit Capillary tube Silencer Compressor Condenser Silencer Figure R-1. Refrigeration Cycle for AH-X08CR/10CR/13CR Indoor unit Evaporator Flare coupling Flare coupling 3-way 2-way valve valve Heating Cooling Silencer Strainer Outdoor unit...
  • Page 26 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR Standard conditions: AH-X08CR / AH-X10CR / AH-X13CR Indoor side Outdoor side Dry-bulb Temp. (˚C) Relative Humidity (%) Dry-bulb Temp. (˚C) Relative Humidity (%) Cooling Temperature at each part and pressure in 3-way valve Model AH-X08CR AH-X13CR AH-X10CR...
  • Page 27 3) Indoor air temp. : Cooling 27˚C, Heating 20˚C (Running frequency: 62Hz) (Running frequency: 50HZ) 1000 Outside air temp.(˚C) Outside air temp.(˚C) Figure P-1. At Cooling for AH-X08CR Figure P-2. At Cooling for AH-X10CR (Running frequency: 81Hz) (Running frequency: 51Hz) 1300 1200...
  • Page 28 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR (Running frequency: 79Hz) (Running frequency: 68Hz) 1100 1000 1000 Outside air temp.(˚C) Outside air temp.(˚C) Figure P-7. At Heating for AY-X08CR Figure P-8. At Heating for AY-X10CR (Running frequency: 96Hz) 1600 1500 1400 1300 1200 Outside air temp.(˚C) Figure P-9.
  • Page 29 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR DISASSEMBLING PROCEDURE FOR INDOOR UNIT [AY-X08BCR/X10CR/X13CR AND AH-X08CR/X10CR/X13CR] SERVICING CAUTION : DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY 1. Open the opne panel, and remove 2 air filters. 5. Pull the front panel up. 2. Remove 4 screws fixing the front panel.
  • Page 30 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR 9. Remove the thermistor of the evaporator. 13. Remove the screw fixing the pipe holder. 10. Remove 4 connectors. 14. Remove 3 screws fixing the control box, and remove the control box. 11. Remove the thermistor holder from the evaporator. 15.
  • Page 31 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR 17. Remove the drain cover from the evaporator. Note: During reassembly, verify that the dew on the pipe is led to the drain pan. 20. Remove 2 screws fixing the motor cover, and pull up the fan. 18.
  • Page 32 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR How to remove the display cover 1. Push the center of display cover from the back. 2. Remove the screw fixing the terminal board. 2. Slide the display cover to the right. How to assemble the display cover 1.
  • Page 33 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR Drain pan and related 1. Remove 3 screws fixing motors. Drain Hose Drain pan Projection Groove To disconned To reconnect 2. Turn the cap area of the drain hose counterclockwise, and remove it from the drain pan. During installation, turn the drain hose to the state of the “engagement position”.
  • Page 34 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR FOR OUTDOOR UNIT [AU-X08CR/X010CR/X13CR, AE-X08CR/X010CR/X13CR] SERVICING CAUTION : DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY Right side view Left side view 1. Loose a screw fixing the side cover. Front view 2. Loose the unit to unit cord. 5.
  • Page 35 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR DISASSEMBLING PROCEDURE OF THE FAN Loose 8. Remove the terminal cover of compressor. 1. Loose the fan nut and fan can take out. 9. Remove 3 terminals of compressor.. 2. Fan motor is secured by 4 screws. 10.
  • Page 36 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR OPTION HOW TO REPLACE THE AIR PURIFYING FILTER (AZ-F900B; (2-sheet package) Electrostatic Type Precautions The filters are sealed in a plastic bag to keep thier dust collection effect. Do not open the bag until using the filters. (Otherwise the filters’ life may get shorter.) Do not expose the filters to direct sunlight.
  • Page 37: Table Of Contents

    AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR Refrigerant Piping Installation / Servicing Manual for Air Condioners Using R-410A TABLE OF CONTENTS Page 1. Outline ................................. 48 1.1 Refrigerant R410A ..........................49 1.2 Safety during Installation / Servicing ...................... 49 2. Refrigerant Piping Installation ........................49 2.1 Pipng Materials and Joint Used ......................
  • Page 38: Outline

    AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR 1. Outline 1. 1 Refrigerant R410A (1) Adoption of R410A in Air Conditioners In 1974, it was pointed out that ozone layer in the upper stratosphere (about 20 ~ 40 km above ground) might have been damaged by the ozone depleting substances such as CFC (chlorofluorocarbon) and HCFC (hydrochlorofluorocarbon).
  • Page 39: Refrigerant R410A

    AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR (3) Lubricationg Oils for R410A As the lubricating oils for R22, mineral oils, alkylbenze synthetic oils, etc. have so far been used. As R410A features less solubility with these conventional lubricating oils such as mineral oils, the lubricating oils tend to stay within the refrigeration cycle.
  • Page 40: Processing Of Piping Materials

    AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR 2.2 Processing of Piping Materials When performing the refrigerant piping installation, care should be taken to ensure that water or dust does not enter the pipe interior, that no other oil other than lubricating oils used in the installed air conditioner is used, and that refrigerant does not leak.
  • Page 41 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR Table 7. Flare and Flare Nut Dimensions for R22 [Unit: mm] Norminal Norminal Thickness Dimension (mm) Flare nut diameter diameter (mm) width (mm) 6.35 9.52 13.0 13.5 12.70 16.2 16.0 12.9 15.88 19.4 19.0 16.0 Fig. 4 Relations between Flare Nut and Flare Seal Surface (2) Flare Connecting Procedures and Precautions a) Make sure that the flare and union portions do not have any scar or dust, etc.
  • Page 42: Storage Of Piping Materials

    AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR 2.3 Storage of Piping Materials (1) Types and Storage of Piping Materials Refrigerant piping materials for air conditioners are broadly classified into the following types. Refrigerant piping General name materials with heat with flare processing : (a) Piping set insulation without flare processing : (b) Copper pipe with insulation...
  • Page 43 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR Table 10. Differences in Port Size between Conventional Manifold and That for R410A Conventional manifold Manifold for R410A 7/16 UNF 1/2 UNF Port size 20 threads per inch 20 threads per inch b) Charge Hose As R410A is characterized by high pressure, the pressure resistance of the charge hose has been increased.
  • Page 44: New Installation Work (When Using New Refrigerant Piping)

    AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR h) Refrigerant Cylinder A refrigerant cylinder exclusive for R410A comes identified with refrigerant name and is coated with pink paint as designated by the ARI, U. S. A Charge Port and Packing for Refrigerant Cylinder According to the charge hose's cap size, a charge port with 1/2 UNF 20 threads per inch and corresponding packing are required.
  • Page 45 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR h) After securing the caps on the control valves, check the capsÅf periphery if there is any gas leakage. 3 4 7 Compound pressure gauge Gauge manifold 76cmHg Handle Lo Handle Hi (always closed) Charge hose Charge hose Vacuum pump adapter Vacuum pump Control valve (2-way)
  • Page 46: Removal (When Using New Refrigerant Piping)

    AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR h) After securintg the caps on the service port and control valve, check the capsÅfperiphery to see if there is any gas leakage. (Liquid side) (Indoor unit) (Outdoor unit) Control valve (2-way) Opened (Gas side) Refrigerant cylinder (with syphon) Control valve (3-way)
  • Page 47: Refrigerant Recharging At Servicing

    AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR 3.6 Refrigerant Recharging at Servicing When it becomes necessary to recharge refrigerant, charge the specified amount of new refrigerant according to the following steps. (For details, see the instruction manual prepared by the equipment manufacturer) 1) Connect the charge hose to the outdoor unit's service port. 2) Connect the charge hose to the vacuum pump abapter.
  • Page 48 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR...
  • Page 49 AH/AY-X08CR AH/AY-X10CR AH/AY-X13CR '02 SHARP CORP. (2U0.10E) Printed in Japan...