9. Light Level Adjustment and ND Shutter Check
Adjust the standard LV value.
Mode
STILL
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
Display data of page 1 (Note 2)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
26, 28
Specified Value
AE level 1: 0FE0 to 1020
AE level 2: Bellow 1100
Note 1: If the data of page: 6, address: 02 is "01", select page: 6, address:
01, set data: 00, and press the PAUSE button.
Note 2: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 01, set data: 0D, and press the PAUSE
button of the adjustment remote commander.
(The light level adjustment is performed and the adjustment
data is stored in page: F, address: 26, 28.)
3)
Select page: 6, address: 02, and check that the data is "01".
• AE level 1 Check
4)
Select page: 0, address: 03, and set data: 06.
5)
Select page: 1, and check that the display data (Note2) satisfies
the AE level 1 specified value.
• AE level 2 Check (MVC-FD90)
6)
Select page: E, address: 41, set data: 6B, and press the PAUSE
button.
7)
Select page: 6, address: 1C, and set data: 03.
8)
Select page: 1, and check that the display data (Note2) satisfies
the AE level 2 specified value.
Processing after Completing Adjustments:
1)
Select page: E, address: 41, set data: 6A, and press the PAUSE
button.
2)
Select page: 6, address: 1C, and set data: 00.
3)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
4)
Select page: 0, address: 03, and set data: 00.
5)
Select page: 0, address: 01, and set data: 00.
(MVC-FD90)
Display data
10. Mixed Color Cancel Adjustment
Perform the mixed color cancel adjustment using the each data of
the color bars.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: This adjustment should be carried out upon completion of "Light
Level Adjustment and ND Shutter Check".
Note 2: If the data of page: 6, address: 02 is "01", select page: 6, address:
01, set data: 00, and press the PAUSE button.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Check that the picture frame is set to the specified position.
(Refer to "8. Picture Frame Setting".)
3)
Select page: 6, address: 01, set data: D7, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 01, set data: D5, and press the PAUSE
button.
(The mixed color cancel adjustment is performed and the
adjustment data is stored in page: F, address: A0 to A3.)
Note: Observe the TV monitor and check that a vertical line is
indicated inside each color zone.
5)
Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button.
2)
Select page: 0, address: 01, and set data: 00.
5-19
STILL
Color bar chart
(Color bar standard picture frame)
F
A0 to A3