11. Auto White Balance Standard Data Input
Adjust the white balance standard data at 3200 K.
Mode
STILL
Subject
Clear chart
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
3A to 3D, 59
Note 1: If the data of page: 6, address: 02 is "01", select page: 6, address:
01, set data: 00, and press the PAUSE button.
Note 2: After the power is turned on, this adjustment can be done only
once.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 01, set data: 11, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 6, address: 01, set data: 0B, and press the PAUSE
button.
(The auto white balance standard data input is performed and
the adjustment data is stored in page: F, address: 3A to 3D, 59)
4) Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments:
1) Select page: 6, address: 01, and set data: 00, and press the
PAUSE button.
2) Select page: 0, address: 01, and set data: 00.
12. White Balance ND Filter Compensation
(MVC-FD90)
Compensate the white balance deviation when ND filter is ON.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: This adjustment should be carried out upon completion of "Auto
White Balance Standard Data Input".
Note 2: If the data of page: 6, address: 02 is "01", select page: 6, address:
01, set data: 00, and press the PAUSE button.
Note 3: After the power is turned on, this adjustment can be done only
once.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 27, after noting down the data, set data:
80, and press the PAUSE button of the adjustment remote
commander.
3) Select page: 6, address: 1C, set data: 03, and wait for 1 second.
4)
Select page: 6, address: 01, set data: 11, and press the PAUSE
button of the adjustment remote commander.
5)
Select page: 6, address: 01, set data: 09, and press the PAUSE
button.
(The white balance ND filter compensation is performed and
the adjustment data is stored in page: F, address: 4F, 50.)
6)
Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments:
1) Select page: 6, address: 1C, set data: 00.
2) Select page: 6, address: 01, and set data: 00, and press the
PAUSE button.
3) Select page: F, address: 27, set the data noted down at step 2)
of "Adjusting method", and press the PAUSE button.
4) Select page: 0, address: 01, and set data: 00.
5-20
STILL
Clear chart
(Color bar standard picture frame)
F
4F, 50