Agc Standard Gain And Max Gain Adjustment; Light Level Adjustment And Nd Shutter Check - Sony DSC-F505 Service Manual

Digital still camera
Hide thumbs Also See for DSC-F505:
Table of Contents

Advertisement

8. AGC Standard Gain and Max Gain Adjustment

Adjust the AGC standard gain and max gain.
Mode
STILL
Subject
Clear chart
(Color bar standard picture frame)
Adjustment Page
E
Adjustment Address
4F
Note: Check that the data of page: 6, address: 02 is "00". If not, turn the
power of the unit OFF/ON.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 5, address: F1, and set data: FF.
3) Select page: 6, address: 98, and set data: C0.
4) Select page: 6, address: 99, and set data: 26.
5) Select page: 6, address: 01, and set data: C7, and press the
PAUSE button of remote commander. (The AGC gain
adjustment is performed and the adjustment data is stored in
page: E, address: 4F, and page: F, address 27.)
6) Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments:
1) Select page: 6, address: 98, and set data: 00.
2) Select page: 6, address: 99, and set data: 00.
3) Select page: 6, address: 01, and set data: 00, and press the
PAUSE button.
4) Select page: 5, address: F1, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.

9. Light Level Adjustment and ND shutter check

Adjust the standard LV value.
Mode
Subject
F
Measurement Point
27
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Check that the data of page: 6, address: 02 is "00". If not, turn the
Note 2: Displayed data of page 1 of the adjustment remote commander.
Adjusting method:
1) Select page: 0, address: 01, set data: 01 and press the PAUSE
button.
2) Select page: 5, address: F1, and set data: FF.
3) Select page: 6, address: 01, set data: 0D, and press the PAUSE
button of the adjustment remote commander.
(The light level adjustment is performed and the adjustment
data is stored in page: F, address: 26, 28.)
4) Select page: 6, address: 02, and check that the data is "01".
5) Select page: 0, address: 03, set data: 06, and press the PAUSE
button.
6) Select page: 1, and check that the display data (Note 2) satisfies
the AE level 1
7) Select page: E, address: 41, set data: 6B, and press the PAUSE
button.
8) Select page: 6, address: 1C, set data: 03, and press the PAUSE
button.
9) Select page: 1, and check that the display data (Note 2) satisfies
the AE level 2.
Processing after Completing Adjustments:
1) Select page: 6, address: 01, and set data: 00.
2) Select page: E, address: 41, set data: 6A, and press the PAUSE
button.
3) Select page: 6, address: 1C, and set data: 00.
4) Select page: 0, address: 03, and set data: 00.
5) Select page: 5, address: F1, and set data: 00.
6) Select page: 0, address: 01, and set data: 00.
5-26
STILL
Clear chart
(Color bar standard picture frame)
Display data of page 1 (Note 2)
Adjustment remote commander
F
26, 28
AE level 1: 0FE0 to 1020
AE level 2: Below 1100
power of the unit OFF/ON.
1 : XX : XX
Display data