Operating Speeds And Limits (912 Uls / S) - Rotax 912 UL Operator's Manual

912 series
Hide thumbs Also See for 912 UL:
Table of Contents

Advertisement

10.1.2 ) Operating speeds and limits (912 ULS / S)

1.
Speed:
Take-off speed ............................ 5800 1/min (5 min.)
Max. continuous speed ............... 5500 1/min
Idle speed ................................... approx. 1400 1/min
2.
Performance (ISA): (International Standard Atmosphere)
Take-off performance .................. 73,5 kW at 5800 1/min
Max. continuous performance ..... 69 kW at 5500 1/min
3.
Acceleration:
Limit of engine operation at zero gravity and in negative "g" condi-
tions
max. ............................................ 5 seconds at max. -0,5 g
4.
Oil pressure:
max. ............................................ 7 bar
■ CAUTION:
min. ............................................. 0,8 bar (12 psi) (below 3500 rpm)
normal ......................................... 2,0 ÷ 5,0 bar (29 ÷ 73 psi) (above
5.
Oil temperature:
max. ............................................ 130 °C ................. (266 °F)
min. ............................................. 50 °C .................... (120 °F)
normal operating temperature ..... approx. 90 ÷ 110 °C(190÷230 °F)
6.
Coolant:
See Operating media Chapter 10.2.1
-
-
7.
Engine start, operating temperature:
max. ............................................ 50 °C ................... (120 °F)
min. ............................................. - 25 °C .................. (- 13 °F)
Effectivity: 912 ULS / S
OM Edition 1 / Rev. 0
For a short period admissible at cold start.
In use of conventional coolant:
Coolant temperature: (coolant exit temperature)
max.....................................................120 °C (248 °F)
Cylinder head temperature:
max.....................................................135 °C (275 °F)
Permanent monitoring of coolant temperature and cylinder head
temperature is necessary.
In use of waterless coolant:
Cylinder head temperature:
max.....................................................135 °C (275 °F)
Permanent monitoring of cylinder head temperature is necessary.
BRP-Rotax
3500 rpm)
page 10 - 5
Jan. 01/2007