DOOR PANEL INSTALLATION
D
oor panel wiring.
Connect the installation wires to the terminal connector,
according to the installation diagrams.
D
escription of the configuration
dip-switch.
The configuration dip-switch is located at the bottom left side of the
circuit, it is accessed by opening the door panel.
Door panel address: dip-switches 1 & 2 in OFF, the door
panel is configured with address "1".
Door panel address: dip-switches 1 in OFF & 2 in ON, the door panel is configured
with address "2".
Do not use.
Do not use.
End of line mode: placed the dip-switch 3 to ON in the door panel where bus wire
terminate. Set to OFF only for intermediate door panel.
1 or 2 apartments mode: placed the dip-switch 4 to ON to configure the door panel with a
system of call to 1 apartment, set to OFF for a system of call to 2 apartments.
Call push button (1 apartment):
*Factory default
Face the door panel to the wall by placing the top at 1,65m.
height and insert the installation wires through the cables
entry.
Drill two holes of 6mm. diameter and insert the wallplugs.
Fix the door panel with especified screws.
Call to apartment 1.
Call to apartment 1.
P
lace the door panel.
Call push button (2 apartments):
Call to apartment 1.
1
2
Call to apartment 2.
1
2