Planet LRP-822CS User Manual page 13

8-port coax + 2-port 10/100/1000t + 2-port 100/1000x sfp long reach poe over coaxial managed switch
Hide thumbs Also See for LRP-822CS:
Table of Contents

Advertisement

User's Manual of LRP-822CS
Intelligent Powered Device Alive Check
The LRP-822CS can be configured to monitor connected PD (Powered Device) status in real time via ping action. Once the PD
stops working and responding, the LRP-822CS will resume the PoE port power and bring the PD back to work. It will greatly
enhance the network reliability through the PoE port resetting the PD's power source and reducing administrator management
burden.
Scheduled Power Recycling
The LRP-822CS allows each of the connected PoE IP cameras or PoE wireless access points via the LRP-101CE to reboot at a
specific time each week. Therefore, it will reduce the chance of IP camera or wireless AP crash resulting from buffer overflow.
PoE Schedule for Energy Saving
Under the trend of energy saving worldwide and contributing to environmental protection, the LRP-822CS can effectively control
the power supply besides its capability of giving high watts power. The "PoE schedule" function helps you to enable or disable
PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises
save power and money. It also increases security by powering off PDs that should not be in use during non-business hours.