Planet ISW-500T User Manual

Industrial 5-18-port compact ethernet switch
Hide thumbs Also See for ISW-500T:

Advertisement

Quick Links

Industrial 5-/8-Port 10/100TX
Compact Ethernet Switch
ISW-500T/ISW-800T
User's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ISW-500T and is the answer not in the manual?

Questions and answers

Summary of Contents for Planet ISW-500T

  • Page 1 Industrial 5-/8-Port 10/100TX Compact Ethernet Switch ISW-500T/ISW-800T User's Manual...
  • Page 2: Table Of Contents

    Table of Contents 1. Package Contents ..................3 2. Product Specifications ..................4 3. Hardware Introduction ................... 6 3.1 Three-View Diagram ................6 3.2 Front View ..................... 8 3.3 LED Definition ..................8 3.4 Top View ....................9 3.5 Wiring the Power Inputs ................9 3.6 Wiring the Fault Alarm Contact ..............
  • Page 3: Package Contents

    1. Package Contents Thank you for purchasing PLANET industrial 5-/8-port 10/100TX Compact Ethernet Switch, ISW-500T/800T. In the following section, the term “Industrial Ethernet Switch” means the ISW-500T or ISW-800T. Open the box of the Industrial Ethernet Switch and carefully unpack it. The box...
  • Page 4: Product Specifications

    2. Product Specifications Product ISW-500T ISW-800T Hardware Specifications Hardware Version 5 x 10/100BASE-TX RJ45 8 x 10/100BASE-TX RJ45 Copper Ports TP auto-MDI/MDI-X, TP auto-MDI/MDI-X, auto negotiation auto negotiation Removable 6-pin terminal block Connector Pin 1/2 for Power 1; Pin 3/4 for fault alarm; Pin 5/6 for Power 2 Provides one relay output for power failure.
  • Page 5 Standards Conformance Switch Processing Scheme Store-and-Forward Address Table 1K entries Shared Data Buffer 448K bits Back pressure for half duplex Flow Control IEEE 802.3x pause frame for full duplex Switch Fabric 1Gbps 1.6Gbps Throughput 0.74Mpps@64bytes 1.19Mpps@ 64 bytes (packet per second) 10/100BASE-TX Network Cables Cat.
  • Page 6: Hardware Introduction

    The LED indicators are also located on the front panel. Top View Mounting Kit Side View Front View Side View Rear View P2 Fault 10/100 DIN-Rail Kit ISW-500T Bottom View Mounting Kit Unit: mm Figure 1: ISW-500T Three-View Diagram...
  • Page 7 Top View Mounting Kit Side View Front View Side View Rear View P2 Alarm DIN-Rail Kit 10/100 ISW-800T Bottom View Mounting Kit Unit: mm Figure 2: ISW-800T Three-View Diagram...
  • Page 8: Front View

    3.2 Front View P2 Alarm P2 Alarm 10/100 10/100 ISW-500T ISW-800T Figure 3: ISW-500T Front View Figure 4: ISW-800T Front View 3.3 LED Definition  System Color Function Green Lights to indicate DC power input 1 has power. Lights to indicate DC power input 2 has power.
  • Page 9: Top View

    1 2 3 4 5 6 DC Input: 12-48V , 0.17A max. PWR1 PWR2 AC Input: 24V , 0.15A max. Figure 5: ISW-500T Top View Max. Fault Alarm Loading: 24V, 1A 1 2 3 4 5 6 DC Input: 12-48V , 0.2A max. PWR1 PWR2 AC Input: 24V , 0.16A max.
  • Page 10 [ISW-500T] 1. Insert positive and negative DC power wires into contacts 1 and 2 for Power 1, or 5 and 6 for Power 2. Max. Fault Alarm Loading: 24V, 1A 1 2 3 4 5 6 DC Input: 12-48V , 0.17A max.
  • Page 11 [ISW-800T] 1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER 1, or contacts 5 and 6 for POWER. Max. Fault Alarm Loading: 24V, 1A 1 2 3 4 5 6 DC Input: 12-48V , 0.2A max. PWR1 PWR2 AC Input: 24V...
  • Page 12: Wiring The Fault Alarm Contact

    3.6 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the Industrial Ethernet Switch will detect the fault status of the power failure and then forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts.
  • Page 13: Installation

    DIN rail and wall. Please read this chapter completely before continuing. This following pictures show the user how to install the device, and the device is not ISW-500T or ISW-800T. 4.1 DIN-rail Mounting Installation...
  • Page 14: Wall-Mount Plate Mounting

    4.2 Wall-mount Plate Mounting Mount on product or wall (Screw size and quantity: 4mm (L), 3mm (dia.) and 4pcs); DIN-rail mount on product (Screw size and quantity: 4mm (L), 3mm (dia.) and 3pcs) 4.3 Side Wall-mount Plate Mounting You must use the screws supplied with the wall-mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty.
  • Page 15: Customer Support

    5. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.
  • Page 16 FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 17 WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately.

This manual is also suitable for:

Lsw-800t

Table of Contents