  • Page 1 8-Port 10/100/1000Mbps 802.3at PoE Desktop Switch GSD-808HP User's Manual...
  • Page 2 Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose.
  • Page 3 Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately. Revision PLANET 8-Port 10/100/1000Mbps 802.3at PoE Desktop Switch User's Manual For Model: GSD-808HP Revision: 3.0 (January 2013) Part No.: 2351-A35130-000...
  • Page 4: Table Of Contents

    Table Of Contents 1. Introduction ....................5 1.1 Checklist ....................5 1.2 Product Description ................. 5 1.3 Features ....................6 1.4 Specification ................... 8 2. Hardware Description ................... 9 2.1 Front Panel .................... 9 2.1.1 LED Indicators ................9 2.2 Rear Panel ....................10 3.
  • Page 5: Introduction

    To facilitate power management, the GSD-808HP equips two orange LEDs hardware designed that located on left side of GSD-808HP front panel, it calls “PoE Power Usage”. 1-4 is meaning that counting from port 1 to 4 of PoE output and 5-8 is meaning that counting from port 5 to 8 of PoE output.
  • Page 6: Features

    Providing data transfer and High Power PoE in one unit, the GSD-808HP shall reduce the need of extension cables and dedicated electrical outlets on the wall, ceiling or any unreachable place. It helps to lower the installation costs and simplify the installation effort.
  • Page 7 9K Jumbo Frame supports at all speed (10/100/1000Mbps) Automatic address learning and address aging Supports Pre-Energy-Efficient Ethernet (EEE) function (IEEE 802.3az) Hardware „ 12-inch desktop size, 1U height LED indicators for PoE ready, PoE activity and PoE Usage Alarm Fanless design Ethernet Link Energy-Saving technology –...
  • Page 8: Specification

    1.4 Specification GSD-808HP Model 8-Port 10/100/1000Mbps 802.3at PoE Desktop Switch Hardware Specification Network Connector 8-Port RJ-45 for 10/100/1000Base-TX PoE Inject Port 8-Port with 802.3af / 802.3at PoE injector function System: Power (Green) PoE Usage Alarm: 1-4 (Orange) LED Display 5-8 (Orange)
  • Page 9: Hardware Description

    Before connecting any network device to the GSD-808HP, please read this chapter carefully. 2.1 Front Panel The Front Panel of the GSD-808HP PoE Ethernet Switch consists of 8x Auto-Sensing 10/100/1000Mbps Ethernet RJ-45 Ports. The LED Indicators are also located on the front panel of the GSD-808HP.
  • Page 10: Rear Panel

    Orange Blink: Indicate the PoE Usage is over 95% 2.2 Rear Panel The rear panel of the GSD-808HP indicates an AC inlet power socket, which accepts input power from 100 to 240V AC, 50-60Hz. 100~240V AC 50 / 60Hz, 2A max.
  • Page 11: Hardware Installation

    1000Base-T, 100Base-TX and 10Base-T networks. Users only need to plug a working network device into one of the 10/100/1000Base-T ports, and then turn on the GSD-808HP. The port will automatically runs in 10Mbps, 20Mbps, 100Mbps or 200Mbps and 1000Mbps or 2000Mbps after the negotiation with the connected device.
  • Page 12: Desktop Installation

    3.1 Desktop Installation To install the Switch on desktop, simply follow the next steps: Step 1: Attach the rubber feet to the recessed areas on the bottom of the Switch, as shown in Figure 3-1. Figure 3-1: Attaching the Rubber Feet to the PoE Fast Ethernet Switch Step 2: Place the Switch on desktop near an AC power source.
  • Page 13: Rack Mounting

    3.2 Rack Mounting To install the Switch in a 19-inch standard rack, follow the instructions described below. Step 1: Place your POE Ethernet Switch on a hard flat surface, with the front panel positioned towards your front side. Step 2: Attach a rack-mount bracket to each side of the Switch with supplied screws attached to the package.
  • Page 14: Product Application

    2.4GHz 802.11n Figure 3-4: Airport / Train Station PoE Switch Connection Cable distance for Switch The cable distance between the GSD-808HP and PC should not exceed 100 meter for UTP/STP cable. Make sure the wiring is correct It can be used Category 3/4/5 cable in 10 Mbps operation. To reli-...
  • Page 15: Ip Office Department / Workgroup Poe Switch

    PLANET IEEE 802.3af compliant IP Phones can be installed without the need of an additional power cable because the power can be provided via the standard Ethernet cable from the connected GSD-808HP. PoE IP Phones and Analog Telephony Adapter work perfectly with the GSD-808HP which injects power through the Ethernet cables.
  • Page 16: Power Over Ethernet Powered Device

    AC sockets. 30 Watts Since the GSD-808HP per PoE port supports 52V DC PoE power output, please check and assure the Powered Device (PD) accept- able DC power range is from 52V DC. Otherwise, it will damage the Note Powered Device (PD).
  • Page 17: Power Over Ethernet Overview

    4. Power Over Ethernet Overview What is PoE? The PoE is an abbreviation of Power over Ethernet; the PoE technology means a system to pass electrical power safely, along with data on Ethernet UTP cable. The IEEE standard for PoE technology requires Category 5 cable or higher for high power PoE levels, but can operate with category 3 cable for low power levels.
  • Page 18 Powered Source Equipment (PSE) Power sourcing equipment (PSE) is a device such as a switch that provides (sources) power on the Ethernet cable. The maximum allowed continuous output power per cable in IEEE 802.3af is 15.40 W. A later specification, IEEE 802.3at, offers 25.50 W.
  • Page 19 The data pairs are used. Since Ethernet pairs are transformer coupled at each end, it is possible to apply DC power to the center tap of the isolation transformer without upsetting the data transfer. In this mode of operation the pair on pins 3 and 6 and the pair on pins 1 and 2 can be of either polarity.
  • Page 20: Troubleshooting

    Why connects PoE device to GSD-808HP and it cannot power on? Solution: Please check the cable type of the connection from GSD-808HP (port 1 to port 8) to the other end. The cable should be an 8-wire UTP, Category 5 or above, EIA568 cable within 100 meters.
  • Page 21: Appendix A Networking Connection

    APPEnDIx A networking Connection A.1 PoE Switch RJ-45 Port Pin Assignments PIN NO RJ-45 SIGNAL ASSIGNMENT Negative Power + 1 2 3 4 5 6 7 8 Negative Power + Positive Power – Positive Power – A.2 Switch's Data RJ-45 Pin Assignments-1000Mbps, 1000Base-T PIN NO MDI-X BI_DA+...
  • Page 22: 10/100Mbps, 10/100Base-Tx

    A.3 10/100Mbps, 10/100Base-TX When connecting Switch to another Fast Ethernet switch, a straight or crossover cable might necessary. Each port of the Switch supports auto-MDI/MDI-X detection. That means you can directly connect the Switch to any Ethernet devices without making a crossover cable. The following table and diagram show the standard RJ- 45 receptacle/connector and their pin assignments: RJ-45 Connector pin assignment MDI-X...
  • Page 23 There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection: SIDE 1 SIDE 2 Straight Cable 1 = White/Orange 1 = White/Orange SIDE 1 2 = Orange 2 = Orange...
  • Page 24: Ec Declaration Of Conformity

    *Model Number: GSD-808HP * Produced by: Manufacturer‘s Name : Planet Technology Corp. Manufacturer‘s Address: 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (2004/108/EC).