How to Re-calibrate the SE-2800 T-Bar

After a firmware update of the switcher it will be necessary to re-calibrate the T-Bar to get it working
correctly.
1. Move the T-Bar to its lowest position.
2. Power OFF the SE-2800 switcher.
3. Press and hold down button 1 on both the
Program and Preset rows of the switcher's
keyboard.
1
2
1
2
4. Power ON the SE-2800 switcher while still
holding down the buttons in step 3.
5. The switcher will start but the keyboard lights
will remain dead except for the T-Bar progress
LEDs. When these LEDs flash ON and OFF
release the buttons from step 3.
38
6. Move the T-Bar to almost its top position
(2-3mm away) and then press the CUT
button.
7. Move the T-Bar back to almost its lowest
position (2-3mm away) and then press the
AUTO TAKE button.
8. To exit the calibration procedure, press the
CLOCK button.
CLOCK
9. Ensure the TIMER button is OFF.