Code 2
(cont.)
Coding in the delivered condition
E6:65
Max. speed of the vari-
able speed heating cir-
cuit pump 65 % of max.
speed in standard mode
E7:30
Min. speed of the vari-
able speed heating cir-
cuit pump 30 % of max.
speed
E8:1
Minimum speed in op-
eration with reduced
room temperature sub-
ject to the setting of
coding address "E9"
E9:45
Speed of the variable
speed heating circuit
pump 45 % of max.
speed in operation with
reduced room tempera-
ture
F1:0
Screed function inactive F1:1
F2:8
Time limit for party
mode or external oper-
ating mode changeover
via key 8 h
F5:12
Run-on time of the inter-
nal circulation pump in
heating mode 12 min
*1
Party mode ends automatically in heating program "rw" when the system changes
over to operation with standard room temperature.
Possible change
E6:0
to
E6:100
E7:0
to
E7:100
E8:0
E9:0
to
E9:100
to
F1:6
F1:15
F2:0
F2:1
*
1
to
F2:12
F5:0
F5:1
to
F5:20
Coding
Maximum speed adjusta-
ble from 0 to 100 %
Minimum speed adjusta-
ble from 0 to 100 % of
max. speed
Speed subject to the set-
ting in coding address
"E7"
Speed adjustable from 0
to 100 % of the maximum
speed during operation
with reduced room tem-
perature
Screed drying function
adjustable in accordance
with 6 optional tempera-
ture/time profiles (see
page 89)
Constant flow tempera-
ture 20 °C
No time limit for party
mode
Time limit adjustable from
*
1 to 12 h
1
No run-on time for the in-
ternal circulation pump
Run-on time of the inter-
nal circulation pump ad-
justable from 1 to 20 min
59