Viessmann VITOLADENS333-F Service Instructions Manual page 49

Type vp3s, 12.9/19.3 kw, 16.1/23.5 kw oil fired compact condensing boiler, for the combustion of low sulphur fuel oil din 51603-el-1
Table of Contents

Advertisement

Code 2
(cont.)
Value
Internal
address
circulation
34: ...
pump
16
ON
17
ON
18
ON
19
ON
20
ON
21
ON
22
ON
23
ON
Coding in the delivered condition
Boiler/burner
51:0
Internal circulation
pump is always started
when there is a heat de-
mand
52:0
Without flow tempera-
ture sensor for low loss
header
Heating cir-
Heating cir-
cuit pump
cuit pump
Heating cir-
Heating cir-
cuit without
cuit with
mixer
mixer
Control
Control funct. Control funct.
funct.
Control
Control funct. OFF
funct.
Control
OFF
funct.
Control
OFF
funct.
OFF
Control funct. Control funct.
OFF
Control funct. OFF
OFF
OFF
OFF
OFF
Possible change
51:1
52:1
Coding
Circulation pump for
cylinder heating
Control funct.
OFF
Control funct.
OFF
When there is a heat de-
mand, the internal circu-
lation pump will only be
started when the burner
is operational. System
with heating water buffer
cylinder.
With flow temperature
sensor for low loss head-
er (automatic adjustment
on connection)