Viessmann VITOLADENS333-F Service Instructions Manual page 52

Type vp3s, 12.9/19.3 kw, 16.1/23.5 kw oil fired compact condensing boiler, for the combustion of low sulphur fuel oil din 51603-el-1
Table of Contents

Advertisement

Coding
Code 2
(cont.)
Coding in the delivered condition
80:1
A fault message is dis-
played, providing a fault
is active for at least 5 s
81:1
Automatic summer/win-
ter time changeover
88:0
Temperature displayed
in °C (Celsius)
8A:175
Never adjust
90:128
Time constant for calcu-
lating the adjusted out-
side temperature
21.3 hours
91:0
No external operating
mode changeover via
external extension
95:0
Without Vitocom 100
communication inter-
face
52
Possible change
80:0
Immediate fault message
80:2
The fault message is is-
to
sued after a delay that is
80:199
adjustable from 10 s to
995 s; 1 step
81:0
Manual summer/winter
time changeover
81:2
Radio clock module is
automatically detected
81:3
With LON communication
module: The control unit
receives the time
88:1
Temperature displayed in
°F (Fahrenheit)
90:0
Fast (low values) or slow
to
(high values) matching of
90:199
the flow temperature,
subject to the set value
when the outside tem-
perature changes;
1 step
91:1
The external heating pro-
gram changeover affects
the heating circuit without
mixer
91:2
The external heating pro-
gram changeover affects
the heating circuit with
mixer
91:3
The external heating pro-
gram changeover affects
the heating circuit without
mixer and the heating cir-
cuit with mixer
95:1
With Vitocom 100 com-
munication interface
(automatic recognition)
5 s
10 min.