Viessmann VITOLADENS333-F Service Instructions Manual page 47

Type vp3s, 12.9/19.3 kw, 16.1/23.5 kw oil fired compact condensing boiler, for the combustion of low sulphur fuel oil din 51603-el-1
Table of Contents

Advertisement

Code 2
(cont.)
Coding in the delivered condition
30:1
Internal variable speed
circulation pump (auto-
matic adjustment)
31:...
Set speed of the inter-
nal circulation pump
when operated as boiler
circuit pump in %, de-
faulted by the boiler
coding card
32:0
Influence of the signal
"External blocking" on
circulation pumps: All
pumps in control func-
tion
Note
Generally, the burner will be blocked when signal "External blocking" is
enabled.
Value
Internal circu-
address
lation pump
32: ...
0
Control funct.
1
Control funct.
2
Control funct.
3
Control funct.
4
Control funct.
5
Control funct.
6
Control funct.
7
Control funct.
8
OFF
9
OFF
10
OFF
11
OFF
12
OFF
13
OFF
14
OFF
15
OFF
Possible change
30:0
31:0
to
31:100
32:1
to
32:15
Heating circuit
Heating circuit
pump
pump
Heating circuit
Heating circuit
without mixer
with mixer
Control funct.
Control funct.
Control funct.
Control funct.
Control funct.
OFF
Control funct.
OFF
OFF
Control funct.
OFF
Control funct.
OFF
OFF
OFF
OFF
Control funct.
Control funct.
Control funct.
Control funct.
Control funct.
OFF
Control funct.
OFF
OFF
Control funct.
OFF
Control funct.
OFF
OFF
OFF
OFF
Coding
Internal circulation pump
without variable speed
(e.g. temporarily for ser-
vice)
Set speed adjustable
from 0 to 100 %
Influence of the signal
"External blocking" on
circulation pumps: see
the following table
Circulation
pump for cylin-
der heating
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
47