4.2
System Programming
[207] Hookswitch Flash Timing Range Selection
Sets the hookswitch flash time range sent from an extension to the system.
MODE 1: 50 to 180 milliseconds.
MODE 2: 80 to 180 milliseconds.
MODE 3: 80 to 650 milliseconds.
MODE 4: 80 to 1000 milliseconds.
MODE 5: 200 to 1000 milliseconds.
2
Default
• Feature Reference
Section 3, Features
Hookswitch Flash
[208] Interdigit Time
Assigns the maximum time allowed between digits for an outgoing outside call.
2
Default
• The interdigit timer applies until the toll restriction check is completed. When the timer
!
!
expires, an outgoing outside call will be disconnected while dialing, if "Enable" was
selected in program [211] "No Dial Disconnection".
• For a single line telephone, an outgoing outside call will be released from a DTMF
receiver when the interdigit timer expires.
• Feature Reference
Section 3, Features
Toll Restriction
0
7
NEXT
(MODE1/MODE2/
MODE 4
0
8
NEXT
10 seconds
STORE
SELECT
MODE3/MODE4/
MODE5)
STORE
SELECT
(5/10/15 sec)
[207]-[208]
END
END
System Programming
4-27