Configuration Settings From Canopy Factory; Bit Handling Capability; Table 8: E1 Framing Specifications; Table 9: Local Terminal And Control Interface Specifications - Motorola Canopy T1/E1 User Manual

Motorola switch user guide
Hide thumbs Also See for Canopy T1/E1:
Table of Contents

Advertisement

Canopy  T1/E1 Multiplexer 
 
 
 

Table 9: Local terminal and control interface specifications

Specification
Type
Mode
Baud Rate
1.3 CONFIGURATION SETTINGS FROM CANOPY FACTORY 
1.3.1
Bit Handling Capability 
As shipped, Canopy T1/E1 Multiplexers transparently pass all T1 or E1 bits regardless of
user framing as
D4
Extended Superframe (ESF)
user encoding as
AMI
B8ZS
HDB3
However, user encoding is helpful for generating meaningful bipolar variation (BPV) data.
Canopy T1/E1 Multiplexers are factory preset to the B8ZS encoding for T1, though easily
changed to another encoding scheme, and are preset as master or slave for timing.
NOTE: To receive the highest level of performance from these units, the user should
understand
clock recovery timing.
packet/frame loss concepts.
delay and latency.
jitter.
 
Issue 3
 
 
 
 
 

Table 8: E1 framing specifications

Specification
Compliance
Framing
Signaling
Description
RS-232 via DB-9 Female Connector
DTE
19.2 kbps
Page 17 of 73 
 
 
 
     
      T1/E1 Multiplexer FPGA Version 3.4 
Description
ITU-T G.703
transparent
transparent
 
September 2004 