Procedure 3: Connecting The Ac Adapter (+3.3 V Dc Power Source); Procedure 4: Connecting The −48 V Dc Power Source - Motorola Canopy T1/E1 User Manual

Motorola switch user guide
Hide thumbs Also See for Canopy T1/E1:
Table of Contents

Advertisement

Canopy  T1/E1 Multiplexer 
 
 
 
WARNING! 
Disconnect power before proceeding.
Follow this procedure to connect the supplied AC adapter (+3.3 v DC power source).

Procedure 3: Connecting the AC adapter (+3.3 v DC power source)

1. Connect the AC adapter to a surge suppression device that meets the standard
specified under
2. Connect the surge suppression device to the building AC power source.
3. Connect the AC adapter to the DC IN port on the rear of the Canopy T1/E1
Multiplexer.
Follow this procedure to connect the to an external −48 v DC power source.
CAUTION! 
Ensure correct polarity before connecting external DC supply to Canopy
T1/E1 Multiplexer.
1. Connect the power cables to the terminal strip ensuring the correct polarity is
maintained.
2. Once the Canopy T1/E1 Multiplexer is mounted in its desired configuration,
connect the supplied terminal strip to the back of the unit. Do this by slowly
pushing the terminal strip into the connector on the back of the Canopy T1/E1
Multiplexer.
 
Issue 3
 
 
 
 
 
Power Supply Unit
end of procedure
Procedure 4: Connecting the −48 v DC power source
 
Page 31 of 73 
 
 
 
     
      T1/E1 Multiplexer FPGA Version 3.4 
 
on Page 27.
 
September 2004 

Advertisement

Table of Contents
loading

Table of Contents