Canopy  T1/E1 Multiplexer 
 
 
 
2.4.6
Configure Timing 
Before the timing may be configured, you need to determine the network timing scheme
to be used. You also need to identify the master and slave devices for the end-user PBX
equipment.
Action
Log in
Set master clock
reference line
Set backup clock
reference line
 
Issue 3
 
 
 
 
 

Procedure 13: Configuring timing using the CLI

Press Enter.
At the username prompt, enter admin.
At the password prompt, enter password.
NOTE: This is the master clock reference for all four T1/E1 lines.
The default setting is T1/E1 Port 1.
Enter set master clock reference line [1/2/3/4]
where
[1/2/3/4] represents T1/E1 ports 1 through 4.
RESULT: The system responds
Clk ref line; [1,2,3,4]
NOTE: This is the optional backup clock reference for all four T1/E1 lines. The
backup clock reference becomes active only when the master clock reference
line is unavailable. The default setting is T1/E1 Port 2.
Enter set secondary clock reference line [1/2/3/4]
where
[1/2/3/4] represents T1/E1 ports 1 through 4.
RESULT: The system responds
Backup clk ref line; [1/2/3/4]