Figure 4-5 Led Display For In-Band Diagnostic - Motorola DCT3412 Installation Manual

High-definition digital video recorder set-top box
Hide thumbs Also See for DCT3412:
Table of Contents

Advertisement

Figure 4-5
LED display for in-band diagnostic
The In-Band Status fields are:
Field
Description
Mode
The values displayed on the OSD are:
Carrier Lock
Indicates whether the in-band receiver is locked to the carrier. If a digital carrier is not
present, it indicates the carrier is not locked:
OSD
YES
NO
Data
Indicates whether data is being carried on the in-band stream. The indicators cover all
packet processors, regardless of the stream they are monitoring:
OSD
YES
NO
SNR
When carrier lock has been established, displays an estimate of the carrier signal-to-noise
ratio in dB, with an explanation:
AGC
When carrier lock has been established, displays an estimate of the automatic gain
control as a percentage, with an explanation:
5 Second Error
Indicates the number of correctable and uncorrectable digital multiplex errors, up to 9999.
Counts
It is updated every 5 seconds and reset each time the DCT3412 is power cycled or
another digital multiplex is tuned. The maximum value displayed is 9999, even if there
were more than 9999 errors.
Data activity indicator
MUTE
IB diagnostic
indicator
(L = locked, U = unlocked)
64 QAM — 64 QAM digital channel
256 QAM — 256 QAM digital channel
LED
Description
L
Carrier locked
U
Carrier not locked
LED
Description
On
In-band data detected within last 5 seconds
Off
In-band data not detected within last 5 seconds
GOOD — Good value
FAIR — Marginal signal level; check the signal
POOR — Unusable signal
INVALID — Invalid SNR value
GOOD — Good value
FAIR — Marginal signal level; check the signal
POOR — Unusable signal
INVALID — Invalid AGC value
P
MUTE
Carrier lock indicator
Diagnostics
4-7
DCT3412 Installation Manual

Advertisement

Table of Contents
loading

Table of Contents