SET-UP

Tractor Set up

Tire Installation (Tractor)

Model MS, MC, MD, MT, MTL, MTEFI
Install the drive tires using the eight (8) lug bolts that
are supplied with the owner's packet of materials. Bolts
are torqued to 75 to 85 ft-lb.
Model MW, MB
Install the drive tires using the eight (8) lug nuts that
are supplied with the owner's packet of materials.
All Models
Check and adjust the inflation of the tires. The tire in-
flation recommendations are:
Drive = 15 PSI (103 kPa)
Rear = 20 PSI (137 kPa)
SERVICE INSTRUCTIONS
July 2006

Battery Service

Model MT, MTL, MTEFI
Model MD, MT, MTL, MTEFI
Raise front mower body up for battery access. Check
the battery for electrolyte level and charge. The elec-
trolyte level should be at the bottom of the vent wells [1/
4 to 1/2 in. (6 to 13 mm) above plates]. If the specific
gravity is less than 1.225, the battery needs charging. If
the battery has been shipped dry, or is wet but needs
service, refer to the following instructions.
Model MS, MC
Tilt mower body up (lift on rear of body) for battery ac-
cess. Check the battery for electrolyte level and charge.
The electrolyte level should be at the bottom of the vent
wells [1/4 to 1/2 in. (6 to 13 mm) above plates]. If the
specific gravity is less than 1.225, the battery needs
charging. If the battery has been shipped dry, or is wet
but needs service, refer to the following instructions.
WALKER MANUFACTURING COMPANY
Page: 1-3
CAUTION
Important Battery Service, Installation, and
Changing Tips for MTEFI:
Do not allow the battery cables to touch
opposing
terminals. When
battery cables attach the positive (+) cable
to positive (+) battery terminal first, followed
by negative (-) cable to negative (-) battery
terminal.
Never start the engine when the cables
are loose or poorly connected to the
battery terminals.
Never disconnect battery while engine is
running.
Never use a quick battery charger to
start the engine.
Never "jump start" the engine using
another source. Electricity fluctuations can
damage the ECU (Electronic Control Unit)
on EFI Models.
Do not charge battery with key switch
"on."
Always disconnect negative (-) battery
cable lead before charging battery, unplug
harness from ECU on EFI Models, before
performing any welding on equipment.
connecting

Hide quick links: