REMKO MKT
Safety Notices
Before delivery, this device was sub-
jected to numerous material, function,
and quality tests. Nevertheless, the
device may present a danger if used by
untrained personnel, improperly, or not
according to regulation!
Caution
Operation other than as de-
scribed in these instructions is
prohibited. Nonobservance leads
to the extinguishment of any
liability and warranty claims.
Observe the following notices:
The device is not suited for out-
■
door operation.
The device may not be set up and
■
operated in rooms at risk of explo-
sion and in atmospheres containing
oil, sulphur, or salt.
Make sure it is at a sufficient
■
security distance to inflammable
objects.
Do not place any objects on the
■
device.
Observe the minimum clearances
■
(Fig. 2).
Do not insert any objects into air
■
inlets and outlets.
Erect the device on an even, stable
■
surface. Never place it on its side
(Fig. 3).
Operate the device only when it is
■
upright.
Do not expose the device to direct
■
water spray.
Operate the device only within its
■
permissible operating limits (16 to
35°C).
Do not pull on or bend the mains
■
supply line.
3
Protect all electrical lines of the
■
device from damage, even from
animals.
Select the extension lines of the
■
mains supply line depending on
the connected load of the device,
the line length, and the intended
use.
Do not lay lines under carpeting.
■
Never operate the device with-
■
out an air filter.
Never direct the air flow at
■
people.
Never open the device housing
■
as there is a danger of an electri-
cal shock.
Work on the cooling system and
■
the electrical equipment may be
carried out only by an
authorised specialist.
Transporting the device
Before transport, switch off the
■
device and pull the mains plug.
Transport the device only in an
■
upright position.
We recommended that any
■
condensate be drained using the
condensate drain spout on the
back side of the device before
transport.
After every transport of the
■
device, wait at least 5 minutes
before recommissioning it
(Fig. 4).
CAUTION
TIP
DANGER
Scope of Supply
1 MKT 250 air conditioner
1 Infrared remote control
2 Batteries (type AAA/1.5 V)
1 Air outlet hose with connection
pipe adapter and win
Control panel
Infrared receiver
Recessed grip
Transport
rollers
Condensate drain spout
with plug
Fig. 1 MKT 250
dow jet
Air directing
plate fins
Air inlet
(circulation air)
with air filter
Exhaust air
outlet
Air outlet
hose
Air inlet
(exhaust air)
Fig. 2
Minimum clearances
Side
500 mm
Front
500 mm
Rear
400 mm
Top
100 mm