These instructions are part of the equipment and must always be kept in the vicinity of the installation or on the equipment This operating manual is a translation of the German original, Version W-04 Made by REMKO Subject to modifications; No liability accepted for errors or misprints!
Outdoor area vaporiser, vaporiser fan, regulation system and condensation pan. The Suction pipe indoor unit can be combined with Control line Outdoor REMKO outdoor units of series Transport and unit Injection pipe MVT 600/900/950/1050 DC packaging with sufficient cooling output. The...
REMKO MXW Combinations Indoor units MXW 200-520 can be combined with MVT series outdoor units. The following combinations are possible. Outdoor unit MVT 600 DC Outdoor unit MVT 900 DC One Indoor unit One indoor unit • • Combination 1 Combination 1 •...
Outdoor unit MVT 950 DC Outdoor unit MVT 1050 DC One indoor unit One indoor unit • • Combination 1 Combination 1 • • Combination 2 Combination 2 • • Combination 3 Combination 3 • • Combination 4 Combination 4 Two indoor units Two indoor units •...
REMKO MXW Operation The indoor unit is easy to operate be activated. receiver of the indoor unit. using an infrared remote control. In manual operation, the following A trouble free reception of data is This is supplied as standard. settings apply:...
Page 9
Buttons on the remote control Buttons on the remote control "FAN" button Press this button to set the "ON/OFF" Button required fan speed. Press this button to start the 4 settings are available: unit. automatic, high, medium and low fan speed. "MODE"...
REMKO MXW Button functions A symbol is shown on the display to indicate that the settings are being transferred. By pressing the ON / OFF button, you can activate or deactivate your ON/OFF Button unit. The programmed settings and adjustment values before the unit was turned off will appear on the display.
Page 11
In cooling mode, the air in the room is cooled down to the set target COOLING Mode temperature. The desired room temperature is set with the ▲/▼buttons in 1 °C increments. If the room temperature is 1 °C above the selected nominal temperature, the indoor unit starts to cool the air in the room.
Page 12
REMKO MXW In the heating mode, you can simultaneously heat all of the rooms in HEATING Mode spring or fall. The desired room temperature is set with the ▲/▼buttons in 1 °C increments. If the room temperature is 1 °C below the selected target temperature, the indoor unit starts to heat the air in the room.
Page 13
In ventilation mode, the air in the room is only circulated. AIR CIRCULATION Mode The room temperature cannot be changed in this mode. The cooling or heating operation is not activated. MODE AIR CIRCULATION The fan speed can be adjusted with this button. A selection can be made FAN Button between low, medium, high and automatic fan speed.
Page 14
REMKO MXW The activation and switch-off time can be programmed with this button. • TIMER Button TIMER-ON / OFF The timer is activated/deactivated by means of pressing the timer on and the timer off button. The timer symbol ON TIMER or OFF TIMER appears.
Clean the fins on the unit prior ■ collection points. to long shutdown periods. Contact REMKO GmbH & Co. KG or your contract partner for a list of specialist companies near you. Type of task Checks/Maintenance/ Inspections •...
REMKO MXW Cleaning the housing Cleaning the filter 8. Close the front side as described above but in reverse 1. Disconnect the power supply to 1. Disconnect the supply voltage order. the unit. to the equipment. 9. Switch the supply voltage back 2.
Troubleshooting and customer service The equipment and components are manufactured using state-of-the-art production methods and tested several times to verify their correct function. If malfunctions should occur, please check the functions as detailed in the list below. For installations with an indoor unit and outdoor unit, refer to the chapter "Troubleshooting and customer service"...
Page 18
REMKO MXW Fault Possible cause Check Remedial measures Filter is dirty / air inlet / outlet Have the filters been cleaned? Clean the filters opening is blocked by by debris Have there been any Doors and windows open / Close doors and windows /...
Installation instructions for qualified personnel Important points prior to Seal off open refrigerant pipes Minimum clearances ■ installation with suitable caps or adhesive strips to avoid the infiltration Observe the minimum clearances For installation of the entire of moisture and never kink or to allow access for maintenance system, observe the operating compress the refrigerant pipes.
REMKO MXW Condensation Installation connection Connection of refrigerant Due to the dew point shortfall, NOTE pipes condensation forms on the Installation should only be vaporiser during the cooling performed by authorised The on-site connection of the operation on the indoor unit.
Electrical connection A protected mains supply cable is The device's scope of delivery Connecting the unit to be connected to the outdoor includes a five metre long, four- unit and 4-core control line is to core control line for connecting the Cover be connected to the indoor unit indoor unit to the outdoor unit.
REMKO MXW Electrical connection diagram Connection MVT 600 DC / MVT 900 DC MVT 950 DC / MVT 1050 DC Indoor unit Outdoor unit Mains cable Phase conductor brown Phase conductor brown 230 V~, Neutral conductor black Neutral conductor black...
Commissioning 4. Check the control system 3. Measure and record all NOTE the required values in the for the unit using the Commissioning should only be functions described in the commissioning report and performed by specially trained chapter "Operation". Timer, check the safety functions.
Exploded view MXW 200 / MXW 260 / MXW 350 / MXW 520 We reserve the right to modify the dimensions and constructional design as part of the ongoing technical development process. Spare parts list Designation MXW 200 MXW 260 MXW 350 MXW 520 Complete front face...
D - 32791 Lage Equipment (machinery) - Implementation: Inverter wall - room air conditioner in multisplit design Series / Model : REMKO MXW 200, MXW 260, MXW 350, MXW 520 Series / Class Number: 782..., 780..., 781..., 779... Applicable regulations :...
Page 28
REMKO, a partner who helps solve problems. Sales REMKO not only has a well- established sales network at home and abroad, it also employs highly trained sales specialists. REMKO Our field staff are more...