Planet VC-820M User Manual page 151

8-port vdsl2+ 2-port gigabit tp-sfp managed switch
Hide thumbs Also See for VC-820M:
Table of Contents

Advertisement

xdsl2PMLCurr15MSes
xdsl2PMLCurr15MLoss
xdsl2PMLCurr15MUas
xdsl2PMLCurr1DayTimeElapsed
xdsl2PMLCurr1DayFecs
xdsl2PMLCurr1DayEs
xdsl2PMLCurr1DaySes
xdsl2PMLCurr1DayLoss
xdsl2PMLCurr1DayUas
LOS-FE >=1 OR RDI >=1 OR LPR-FE >=1 .
This parameter is inhibited during UAS
Count of seconds during this interval that there was:
VTU-C: (CRC-8 anomalies in one or more of the received bearer
channels) >= 18 OR LOS >= 1 OR SEF >= 1 OR LPR >= 1
VTU-R: (FEBE anomalies in one or more of the received bearer
channels) >= 18 OR LOS-FE >= 1 OR RDI >= 1 OR
LPR-FE >= 1
This parameter is inhibited during UAS.
Count of seconds during this interval that there was LOS (or LOS-FE for
VTU-R
Count of seconds in Unavailability State during this interval. Unavailability
begins at the onset of 10 contiguous severely-errored seconds, and ends
at the onset of 10 contiguous seconds with no severely-errored seconds
Total elapsed seconds in this interval
Count of seconds during this interval that there was at least one FEC
correction event for one or more bearer channels in this line. This
parameter is inhibited during UAS or SES
Count of seconds during this interval that there was:
VTU-C: CRC-8 >= 1 for one or more bearer channels OR
LOS >= 1 OR SEF >= 1 OR LPR >= 1
VTU-R: FEBE >= 1 for one or more bearer channels OR
LOS-FE >= 1 OR RDI >= 1 OR LPR-FE >= 1.
This parameter is inhibited during UAS.
Count of seconds during this interval that there was:
VTU-C: (CRC-8 anomalies in one or more of the
received bearer channels) >= 18 OR LOS >= 1
OR SEF >= 1 OR LPR >= 1
VTU-R: (FEBE anomalies in one or more of the
received bearer channels) >= 18 OR LOS-FE >= 1
OR RDI >= 1 OR LPR-FE >= 1 .
This parameter is inhibited during UAS
Count of seconds during this interval that there was LOS (or LOS-FE for
VTU-R
Count of seconds in Unavailability State during this interval.
Unavailability begins at the onset of 10 contiguous severely-errored
seconds, and ends at the onset of 10 contiguous seconds with no
severely-errored seconds