Fault codes
(cont.)
Fault
Const.
Weath.-
code
comp.
on the
display
F9
X
X
FA
X
X
Fd
X
X
FE
X
X
FF
X
X
System char-
Cause
acteristics
Burner in a
Fan speed
fault state
too low dur-
ing burner
start
Burner in a
Fan not at
fault state
standstill
Burner
Fault at the
blocked
burner con-
trol unit
Burner
Strong inter-
blocked or in a
ference
fault state
(EMC) field
nearby, or
faulty main
PCB
Burner
Strong inter-
blocked or in a
ference
fault state
(EMC) field
nearby, or in-
ternal fault
Troubleshooting
Measures
Check the fan, fan
connecting
cables, fan power
supply and con-
trol; press "E"
Check the fan, fan
connecting cables
and fan control;
press "E"
Check the ignition
electrodes and
connecting
cables/leads;
check for any
strong interfer-
ence (EMC) field
near the equip-
ment; press "E".
Replace the con-
trol unit if the fault
persists
Start the equip-
ment again. Re-
place the control
unit if the equip-
ment will not re-
start.
Start the equip-
ment again. Re-
place the control
unit if the equip-
ment will not re-
start.